Finite Element Model Updating and Damage Prediction for Historical Timber Buildings: Case Study of a Pavilion in Kai-Yuan Temple, China

Historical timber buildings have sustained various forms of damage over extended periods due to material degradation, wind loads, and seismic actions. Establishing an accurate finite element (FE) model and predicting the damage progression in such structures remain significant challenges. Therefore, this study proposed a model-updating method for historical timber buildings. The existing damage in historical timber buildings was captured using three-dimensional (3D) laser scanning technology. Subsequently, the initially established FE model was updated by response surface (RS) optimization and the multiobjective genetic algorithm (MOGA). Additionally, a structural damage prediction method for historical buildings was introduced based on the updated model. The proposed methodology was applied to a pavilion located in Kaiyuan Temple, Fujian Province, China. An FE model considering existing damage was established and updated in ANSYS, enabling an accurate assessment and prediction of damage progression. The model-updating process demonstrated significant improvement, with average discrepancies in mortise-tenon separation and structural inclination between the FE model and the actual structure reduced by 79% and 69.5%, respectively. Particularly, the maximum percentage discrepancy decreased from 25.5% to approximately 5%. Furthermore, the continuous increase in the uneven settlement of foundation has a great impact on the safety of the pavilion. Therefore, damage progression was predicted by simulating increased uneven foundation settlement. The results indicated that both mortise-tenon separation and structural inclination would exceed the critical limit value when the pillar settlement exceeds 2.5 mm. This study provides a robust and practical method for model updating and damage prediction in historical timber buildings, offering valuable insights for their preservation and structural assessment.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2026-01-30
DOI
https://doi.org/10.1061/jsendh.steng-15008
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Model Updating and Damage Prediction for Historical Timber Buildings: Case Study of a Pavilion in Kai-Yuan Temple, China

Yuhang Li, Lei Li, Lixin Shen, Yang Deng et al.
Journal of Structural Engineering
Masonry and Concrete Structural Analysis
article

Finite Element Model Updating and Damage Prediction for Historical Timber Buildings: Case Study of a Pavilion in Kai-Yuan Temple, China

Yuhang Li, Lei Li, Lixin Shen, Yang Deng, Jingshu Wu
article en

Abstract

Historical timber buildings have sustained various forms of damage over extended periods due to material degradation, wind loads, and seismic actions. Establishing an accurate finite element (FE) model and predicting the damage progression in such structures remain significant challenges. Therefore, this study proposed a model-updating method for historical timber buildings. The existing damage in historical timber buildings was captured using three-dimensional (3D) laser scanning technology. Subsequently, the initially established FE model was updated by response surface (RS) optimization and the multiobjective genetic algorithm (MOGA). Additionally, a structural damage prediction method for historical buildings was introduced based on the updated model. The proposed methodology was applied to a pavilion located in Kaiyuan Temple, Fujian Province, China. An FE model considering existing damage was established and updated in ANSYS, enabling an accurate assessment and prediction of damage progression. The model-updating process demonstrated significant improvement, with average discrepancies in mortise-tenon separation and structural inclination between the FE model and the actual structure reduced by 79% and 69.5%, respectively. Particularly, the maximum percentage discrepancy decreased from 25.5% to approximately 5%. Furthermore, the continuous increase in the uneven settlement of foundation has a great impact on the safety of the pavilion. Therefore, damage progression was predicted by simulating increased uneven foundation settlement. The results indicated that both mortise-tenon separation and structural inclination would exceed the critical limit value when the pillar settlement exceeds 2.5 mm. This study provides a robust and practical method for model updating and damage prediction in historical timber buildings, offering valuable insights for their preservation and structural assessment.

Journal of Structural EngineeringVol. 152(4)
Metallurgical Corporation of China (China) (CN), Beijing Polytechnic (CN), Beijing University of Civil Engineering and Architecture (CN)
Sustainable cities and communities
Openalex Percentile: Top 72%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.