ASSESSMENT OF RADIATION SAFETY MEASURES IN SELECT RADIO-DIAGNOSTIC CENTRES IN KADUNA STATE, NIGERIA

Background: The risks associated with x-rays in radiography are minimized through international best practices of a regular program of quality control. Objective: To assess the radiation safety precautions taken in five radio-diagnostic centers in Kaduna State, Nigeria. Methodology: Measuring tapes, radiation meters and other accessories were used to assess for x-ray room dimension, x-ray tube leakage, kVp accuracy, half value layer (HVL), mA linearity, optical and x-ray beam congruence, beam alignment, and timer accuracy. Results: Only one centre complied with the 16m² minimum room dimension required for an x-ray room, passed area monitoring without a compromise, and wholly complied with kVp error limit of 5%. Two centres passed optical radiation beam congruence, beam alignment and timer accuracy tests. Three centres passed mA linearity test. All the five centers passed the tube leakage test with none of the centers recording up to 1 mSv/h at 100 cm from the tube surface. Conclusion: X-ray machines used in Kaduna States are safe. However, there are uncoordinated attention to other safety precautions. More efforts should be made to ensure that holistic regulatory standards are met in order to consolidate radiation protection.

Authors

Institutions

Publication Details

Journal
JRRS
Published
2026-01-12
DOI
https://doi.org/10.82547/jrrs.vol29no1.97
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ASSESSMENT OF RADIATION SAFETY MEASURES IN SELECT RADIO-DIAGNOSTIC CENTRES IN KADUNA STATE, NIGERIA

O.H. Adams, Uloma Nwogu, Thomas Adejoh, Patrick Akoji Ida et al.
JRRS
Radiation Dose and Imaging
article

ASSESSMENT OF RADIATION SAFETY MEASURES IN SELECT RADIO-DIAGNOSTIC CENTRES IN KADUNA STATE, NIGERIA

O.H. Adams, Uloma Nwogu, Thomas Adejoh, Patrick Akoji Ida, Musa Y. Dambele, Hyacienth U. Chiegwu
article en

Abstract

Background: The risks associated with x-rays in radiography are minimized through international best practices of a regular program of quality control. Objective: To assess the radiation safety precautions taken in five radio-diagnostic centers in Kaduna State, Nigeria. Methodology: Measuring tapes, radiation meters and other accessories were used to assess for x-ray room dimension, x-ray tube leakage, kVp accuracy, half value layer (HVL), mA linearity, optical and x-ray beam congruence, beam alignment, and timer accuracy. Results: Only one centre complied with the 16m² minimum room dimension required for an x-ray room, passed area monitoring without a compromise, and wholly complied with kVp error limit of 5%. Two centres passed optical radiation beam congruence, beam alignment and timer accuracy tests. Three centres passed mA linearity test. All the five centers passed the tube leakage test with none of the centers recording up to 1 mSv/h at 100 cm from the tube surface. Conclusion: X-ray machines used in Kaduna States are safe. However, there are uncoordinated attention to other safety precautions. More efforts should be made to ensure that holistic regulatory standards are met in order to consolidate radiation protection.

JRRS
University of Nigeria (NG), Nnamdi Azikiwe University (NG), Ahmadu Bello University Teaching Hospital (NG), Nnamdi Azikiwe University Teaching Hospital (NG), University of Benin (NG), Bayero University Kano (NG)
Openalex Percentile: Top 72%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.