Dual-mode endoscopic probe for optical coherence tomography and plasma ablation

We present a novel dual-mode endoscopic probe that integrates optical coherence tomography with low-temperature plasma ablation. A key challenge in endoscopic therapy is achieving precise tissue removal without damaging adjacent healthy layers, which requires both minimizing thermal damage and real-time monitoring of tissue changes. In this study, low-temperature plasma ablation was employed to achieve tissue removal with minimal thermal damage. A dual-mode configuration was realized by integrating the plasma electrode with OCT for ablation and monitoring. This integrated design can help reduce procedure-related complications. The probe measured 5[Formula: see text]mm in diameter with a 40[Formula: see text]mm rigid length and achieved 20 [Formula: see text] [Formula: see text]m lateral resolution at a 5[Formula: see text]mm working distance in air. A piezoelectric bender driven at 278.5[Formula: see text]Hz induced a single-mode fiber resonance for a 1.88[Formula: see text]mm lateral scanning range. A coaxial needle-shaped plasma ablation electrode, validated through both simulations and experiments, ensured stable plasma generation with a low ablation temperature at a peak voltage of 120[Formula: see text]V. Functional validation on ex vivo porcine large and small intestine tissues demonstrated precise monitoring of ablation progression with minimal thermal damage, highlighting its potential for minimally invasive therapies.

Authors

Institutions

Publication Details

Journal
Journal of Innovative Optical Health Sciences
Published
2026-01-30
DOI
https://doi.org/10.1142/s179354582640002x
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-mode endoscopic probe for optical coherence tomography and plasma ablation

Rui Bao, Chengli Song, Zixuan Yin, Xingyu Liu et al.
Journal of Innovative Optical Health Sciences
Optical Coherence Tomography Applications
article

Dual-mode endoscopic probe for optical coherence tomography and plasma ablation

Rui Bao, Chengli Song, Zixuan Yin, Xingyu Liu, Liuxiao Chen, Minghui Chen, Haochen Hu, Jiahui Ye
article en

Abstract

We present a novel dual-mode endoscopic probe that integrates optical coherence tomography with low-temperature plasma ablation. A key challenge in endoscopic therapy is achieving precise tissue removal without damaging adjacent healthy layers, which requires both minimizing thermal damage and real-time monitoring of tissue changes. In this study, low-temperature plasma ablation was employed to achieve tissue removal with minimal thermal damage. A dual-mode configuration was realized by integrating the plasma electrode with OCT for ablation and monitoring. This integrated design can help reduce procedure-related complications. The probe measured 5[Formula: see text]mm in diameter with a 40[Formula: see text]mm rigid length and achieved 20 [Formula: see text] [Formula: see text]m lateral resolution at a 5[Formula: see text]mm working distance in air. A piezoelectric bender driven at 278.5[Formula: see text]Hz induced a single-mode fiber resonance for a 1.88[Formula: see text]mm lateral scanning range. A coaxial needle-shaped plasma ablation electrode, validated through both simulations and experiments, ensured stable plasma generation with a low ablation temperature at a peak voltage of 120[Formula: see text]V. Functional validation on ex vivo porcine large and small intestine tissues demonstrated precise monitoring of ablation progression with minimal thermal damage, highlighting its potential for minimally invasive therapies.

Journal of Innovative Optical Health Sciences
University of Shanghai for Science and Technology (CN)
Openalex Percentile: Top 72%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual-mode endoscopic probe for optical coherence tomography and plasma ablation — Rui Bao, Chengli Song, et al. · Journal of Innovative Optical Health Sciences (2026) | TGRS Research Map | TGRS