Operational study of a 200,000 tonne/yr partial oxy-fuel combustion CO2 capture project for cement production

• An oxy-fuel calciner system for CO 2 capture in the cement industry is presented. • Industrial tests conducted under three combustion modes: air, hybrid and oxy-fuel. • Operational parameters were compared between oxy-fuel and air combustion. • The system achieved a flue gas with 82.7 vol% CO 2 and a product purity of 99.95 wt%. Oxy-fuel combustion presents a viable pathway for achieving near-zero carbon emissions in cement production, significantly reducing flue gas volume while enhancing CO 2 concentration to minimize capture costs. However, elevated CO 2 concentration impede raw meal decomposition in calciner, constituting a constraint for oxy-fuel combustion application. This study evaluated the world’s first industrial-scale 200,000 tonne/yr partial oxy-fuel combustion (oxy-fuel calciner) system in the cement sector, operational in China since 2024. The newly built oxy-fuel calciner operates with flexible transitions between air combustion, oxy-fuel combustion and hybrid combustion conditions, while the original rotary kiln and the pre-existing calciner remain to operate in air combustion condition. Operational results of the oxy-fuel calciner system indicated an average preheater outlet flue gas CO 2 concentration of 82.7 % in oxy-fuel combustion condition, marking a 47.5 % increase over air combustion, with a daily output of 667 tonnes of 99.95 % pure CO 2 production. To mitigate the inhibitory effects of high CO 2 on carbonate decomposition, calciner temperatures required elevation by 27–32 °C, achieving a raw meal calcination rate of 90–93 %. Notably, preheater outlet flue gas temperatures averaged 203 °C, 33 °C lower than air combustion, due to reduced gas volumes despite higher calciner temperatures. Real-time monitoring detected O 2 concentration variations, with air combustion at 1.7–2.6 %, hybrid combustion at 2.4–4.2 % and oxy-fuel operation at 2.0–5.2 %. The study also revealed that increased oxygen utilization exacerbates thermal and pressure instabilities, particularly impacting clinker free-CaO control in kiln operation.

Authors

Institutions

Publication Details

Journal
International journal of greenhouse gas control
Published
2026-01-30
DOI
https://doi.org/10.1016/j.ijggc.2026.104585
Primary Topic
Chemical Looping and Thermochemical Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operational study of a 200,000 tonne/yr partial oxy-fuel combustion CO2 capture project for cement production

Zhouzheng Jin, Xueping Peng, Chenghang Zheng, Xiang Gao et al.
International journal of greenhouse gas control
Chemical Looping and Thermochemical Processes
article

Operational study of a 200,000 tonne/yr partial oxy-fuel combustion CO2 capture project for cement production

Zhouzheng Jin, Xueping Peng, Chenghang Zheng, Xiang Gao, Changhua Chen
article en

Abstract

• An oxy-fuel calciner system for CO 2 capture in the cement industry is presented. • Industrial tests conducted under three combustion modes: air, hybrid and oxy-fuel. • Operational parameters were compared between oxy-fuel and air combustion. • The system achieved a flue gas with 82.7 vol% CO 2 and a product purity of 99.95 wt%. Oxy-fuel combustion presents a viable pathway for achieving near-zero carbon emissions in cement production, significantly reducing flue gas volume while enhancing CO 2 concentration to minimize capture costs. However, elevated CO 2 concentration impede raw meal decomposition in calciner, constituting a constraint for oxy-fuel combustion application. This study evaluated the world’s first industrial-scale 200,000 tonne/yr partial oxy-fuel combustion (oxy-fuel calciner) system in the cement sector, operational in China since 2024. The newly built oxy-fuel calciner operates with flexible transitions between air combustion, oxy-fuel combustion and hybrid combustion conditions, while the original rotary kiln and the pre-existing calciner remain to operate in air combustion condition. Operational results of the oxy-fuel calciner system indicated an average preheater outlet flue gas CO 2 concentration of 82.7 % in oxy-fuel combustion condition, marking a 47.5 % increase over air combustion, with a daily output of 667 tonnes of 99.95 % pure CO 2 production. To mitigate the inhibitory effects of high CO 2 on carbonate decomposition, calciner temperatures required elevation by 27–32 °C, achieving a raw meal calcination rate of 90–93 %. Notably, preheater outlet flue gas temperatures averaged 203 °C, 33 °C lower than air combustion, due to reduced gas volumes despite higher calciner temperatures. Real-time monitoring detected O 2 concentration variations, with air combustion at 1.7–2.6 %, hybrid combustion at 2.4–4.2 % and oxy-fuel operation at 2.0–5.2 %. The study also revealed that increased oxygen utilization exacerbates thermal and pressure instabilities, particularly impacting clinker free-CaO control in kiln operation.

International journal of greenhouse gas controlVol. 151
Tianjin Municipal Engineering Design and Research Institute (CN), Zhejiang Energy Research Institute (CN), State Key Laboratory of Clean Energy Utilization, Zhejiang University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 72%
Chemical Looping and Thermochemical Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.