Nanobubbles Affect Analyte Translocation through Glass Nanopores by Inducing Two-Stage Current Signals

Noise reduction has long been a key focus for enhancing the accuracy of nanopore detection, and bubbles are a primary source of noise in nanopores. However, the effect of bubbles on the translocation process of analytes in nanopores has not been thoroughly studied. This study found, through a combination of experiments and simulations, that bubbles can distort the translocation current of analytes, making it difficult to accurately characterize analyte size through current. At the same time, a detailed analysis was conducted on the specific effects of bubble size and position on translocation current. This achievement helps to eliminate the interference of bubbles on analyte translocation events and improves the accuracy of signal detection.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-30
DOI
https://doi.org/10.1021/acs.analchem.5c05902
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanobubbles Affect Analyte Translocation through Glass Nanopores by Inducing Two-Stage Current Signals

T. Feng, Yuying Zhou, Xiang Ao
Analytical Chemistry
Nanopore and Nanochannel Transport Studies
article

Nanobubbles Affect Analyte Translocation through Glass Nanopores by Inducing Two-Stage Current Signals

T. Feng, Yuying Zhou, Xiang Ao
article en

Abstract

Noise reduction has long been a key focus for enhancing the accuracy of nanopore detection, and bubbles are a primary source of noise in nanopores. However, the effect of bubbles on the translocation process of analytes in nanopores has not been thoroughly studied. This study found, through a combination of experiments and simulations, that bubbles can distort the translocation current of analytes, making it difficult to accurately characterize analyte size through current. At the same time, a detailed analysis was conducted on the specific effects of bubble size and position on translocation current. This achievement helps to eliminate the interference of bubbles on analyte translocation events and improves the accuracy of signal detection.

Analytical ChemistryVol. 98(5)
Chinese Academy of Sciences (CN), Institute of Microelectronics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 72%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.