Theoretical framework for soft X-ray Fourier transform spectroscopy using the Wigner function

This work presents a theoretical framework for the propagation of partially coherent Gaussian radiation in a modified Mach-Zehnder interferometer designed for Fourier transform spectroscopy (FTS) applications. Using the Wigner function formalism, we analytically propagate the radiation through the system and benchmark our approach by comparing the resulting interference pattern and interferogram with previous works in the diffraction limit. Our analysis reveals that the transverse coherence length requirement of the incident light field for detectable modulation is less stringent than previously assumed. Additionally, we provide theoretical demonstrations of FTS performance across various wavelengths using the proposed setup. These findings underscore the potential of this interferometer to achieve high-resolution FTS in the soft X-ray regime.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2026-01-26
DOI
https://doi.org/10.1107/s1600577525011452
Primary Topic
Quantum optics and atomic interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical framework for soft X-ray Fourier transform spectroscopy using the Wigner function

C Chen, Andrew Lindburg, Per-Anders Glans, Honghe Ding et al.
Journal of Synchrotron Radiation
Quantum optics and atomic interactions
article

Theoretical framework for soft X-ray Fourier transform spectroscopy using the Wigner function

C Chen, Andrew Lindburg, Per-Anders Glans, Honghe Ding, Antoine Wojdyla, Jinghua Guo
article en

Abstract

This work presents a theoretical framework for the propagation of partially coherent Gaussian radiation in a modified Mach-Zehnder interferometer designed for Fourier transform spectroscopy (FTS) applications. Using the Wigner function formalism, we analytically propagate the radiation through the system and benchmark our approach by comparing the resulting interference pattern and interferogram with previous works in the diffraction limit. Our analysis reveals that the transverse coherence length requirement of the incident light field for detectable modulation is less stringent than previously assumed. Additionally, we provide theoretical demonstrations of FTS performance across various wavelengths using the proposed setup. These findings underscore the potential of this interferometer to achieve high-resolution FTS in the soft X-ray regime.

Journal of Synchrotron RadiationVol. 33(2)
Lawrence Berkeley National Laboratory (US), Arizona State University (US)
Openalex Percentile: Top 69%
Quantum optics and atomic interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.