Time-domain stability analysis of mixed generation electric power system subject to severe disturbance: Test of control parameter adjustments for increased renewable energy penetration

Power systems with high penetration of inverter-based generation face severe stability challenges due to reduced inertia and altered transient behavior during disturbances. Addressing these challenges is crucial to ensure reliable operation in the ongoing energy transition. In this study, a detailed mixed-generation system composed of synchronous machines and inverter-based generators is modeled and analyzed under severe disturbances using Time-Domain Simulation (TDS). The proposed framework systematically tests combinations of physical and control parameter adjustments – such as system inertia, power controller gains, phase-locked loop (PLL) gains, and power reference control – to identify the mechanisms that enhance transient stability at various renewable penetration levels. Unlike previous studies that rely on simplified linear or small-signal models, this work employs high-fidelity nonlinear dynamic modeling implemented in DIgSILENT PowerFactory, enabling quantitative assessment of stability boundaries for renewable shares ranging from 10% to 90%. The results demonstrate how coordinated parameter tuning can increase the maximum stable renewable penetration while maintaining system robustness. This study provides practical insights for grid operators and researchers by linking each renewable penetration level with the minimum parameter adjustments required to ensure transient stability in mixed-generation systems • A mixed-generation testbed is modeled with high-fidelity nonlinear dynamics. • Transient stability is evaluated under severe faults for 10%–90% renewable shares. • A systematic tuning of PLL, PC, PR, and inertia reveals stability mechanisms. • Minimum parameter adjustments required for each RPL level are identified. • Coordinated control tuning enables stability even at 90% renewable penetration.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-01-30
DOI
https://doi.org/10.1016/j.egyr.2026.109062
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-domain stability analysis of mixed generation electric power system subject to severe disturbance: Test of control parameter adjustments for increased renewable energy penetration

David Osorio-García, Agustin Irizarry
Energy Reports
Power System Optimization and Stability
article

Time-domain stability analysis of mixed generation electric power system subject to severe disturbance: Test of control parameter adjustments for increased renewable energy penetration

David Osorio-García, Agustin Irizarry
article en

Abstract

Power systems with high penetration of inverter-based generation face severe stability challenges due to reduced inertia and altered transient behavior during disturbances. Addressing these challenges is crucial to ensure reliable operation in the ongoing energy transition. In this study, a detailed mixed-generation system composed of synchronous machines and inverter-based generators is modeled and analyzed under severe disturbances using Time-Domain Simulation (TDS). The proposed framework systematically tests combinations of physical and control parameter adjustments – such as system inertia, power controller gains, phase-locked loop (PLL) gains, and power reference control – to identify the mechanisms that enhance transient stability at various renewable penetration levels. Unlike previous studies that rely on simplified linear or small-signal models, this work employs high-fidelity nonlinear dynamic modeling implemented in DIgSILENT PowerFactory, enabling quantitative assessment of stability boundaries for renewable shares ranging from 10% to 90%. The results demonstrate how coordinated parameter tuning can increase the maximum stable renewable penetration while maintaining system robustness. This study provides practical insights for grid operators and researchers by linking each renewable penetration level with the minimum parameter adjustments required to ensure transient stability in mixed-generation systems • A mixed-generation testbed is modeled with high-fidelity nonlinear dynamics. • Transient stability is evaluated under severe faults for 10%–90% renewable shares. • A systematic tuning of PLL, PC, PR, and inertia reveals stability mechanisms. • Minimum parameter adjustments required for each RPL level are identified. • Coordinated control tuning enables stability even at 90% renewable penetration.

Energy ReportsVol. 15
University of Puerto Rico System (PR)
Affordable and clean energy
Openalex Percentile: Top 72%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Time-domain stability analysis of mixed generation electric power system subject to severe disturbance: Test of control parameter adjustments for increased renewable energy penetration — David Osorio-García, Agustin Irizarry · Energy Reports (2026) | TGRS Research Map | TGRS