Rapid Diagnosis of <i>Staphylococcus Aureus</i> Using The Lamp Method

Methicillin-resistant Staphylococcus aureus (MRSA), a genetically distinct strain of S. aureus, poses a significant health problem in humans and animals. MRSA is responsible for various difficult-to-treat illnesses in humans and animals. The loop-mediated isothermal amplification (LAMP) experiment was performed using four unique primers developed for six distinct mecA and femA gene sequences. The LAMP test was completed in 45 minutes at 62.5°C and visualized by gel electrophoresis. Moreover, the LAMP test has better sensitivity than conventional PCR, detecting genomic DNA at 64.8 pg/μL, which is hundreds of times more sensitive than conventional PCR. The LAMP test is an attractive, potentially fascinating strategy for rapid detection of S. aureus that can be applied in laboratories and field settings with available budgets.

Authors

Publication Details

Journal
AUIQ Conference Proceedings
Published
2026-01-29
DOI
https://doi.org/10.70176/3107-2682.1008
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Diagnosis of Staphylococcus Aureus Using The Lamp Method

Hadeel Abdul-Amir, Thair Al-Kelabi
AUIQ Conference Proceedings
Biosensors and Analytical Detection
article

Rapid Diagnosis of Staphylococcus Aureus Using The Lamp Method

Hadeel Abdul-Amir, Thair Al-Kelabi
article en

Abstract

Methicillin-resistant Staphylococcus aureus (MRSA), a genetically distinct strain of S. aureus, poses a significant health problem in humans and animals. MRSA is responsible for various difficult-to-treat illnesses in humans and animals. The loop-mediated isothermal amplification (LAMP) experiment was performed using four unique primers developed for six distinct mecA and femA gene sequences. The LAMP test was completed in 45 minutes at 62.5°C and visualized by gel electrophoresis. Moreover, the LAMP test has better sensitivity than conventional PCR, detecting genomic DNA at 64.8 pg/μL, which is hundreds of times more sensitive than conventional PCR. The LAMP test is an attractive, potentially fascinating strategy for rapid detection of S. aureus that can be applied in laboratories and field settings with available budgets.

AUIQ Conference ProceedingsVol. 1(1)
Openalex Percentile: Top 73%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.