Laboratory investigation of reinforcement spacing effect on geosynthetic-block connection

This study investigates the connection between geogrid reinforcement and modular concrete block facings using a laboratory testing device that simulates the key mechanisms in segmental geosynthetic reinforced structures. The device enables the assessment of various factors influencing connection loads, including vertical spacing effects. A comprehensive instrumentation program was implemented to measure lateral earth pressures, geosynthetic strains, and loads within a geosynthetic-reinforced unit cell subjected to incremental surcharge stages. The findings highlight the significant impact of closely spaced geogrid reinforcements on connection load behavior in segmental geosynthetic walls. Reducing vertical spacing while maintaining Sv/Tult ratio led to a more uniform distribution of horizontal displacements along the facing wall and a substantial reduction in relative settlements. This reduction suggests that closely spaced reinforcements effectively mitigate the down-drag effect altering the mechanisms governing connection load development and, consequently, influence the appropriate methodology for calculating required connection loads in design analysis.

Authors

Institutions

Publication Details

Journal
Geosynthetics International
Published
2026-01-30
DOI
https://doi.org/10.1680/jgein.25.00050
Primary Topic
Geotechnical Engineering and Soil Stabilization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laboratory investigation of reinforcement spacing effect on geosynthetic-block connection

F. H. M. Portelinha, P. V. C. Figueiredo
Geosynthetics International
Geotechnical Engineering and Soil Stabilization
article

Laboratory investigation of reinforcement spacing effect on geosynthetic-block connection

F. H. M. Portelinha, P. V. C. Figueiredo
article en

Abstract

This study investigates the connection between geogrid reinforcement and modular concrete block facings using a laboratory testing device that simulates the key mechanisms in segmental geosynthetic reinforced structures. The device enables the assessment of various factors influencing connection loads, including vertical spacing effects. A comprehensive instrumentation program was implemented to measure lateral earth pressures, geosynthetic strains, and loads within a geosynthetic-reinforced unit cell subjected to incremental surcharge stages. The findings highlight the significant impact of closely spaced geogrid reinforcements on connection load behavior in segmental geosynthetic walls. Reducing vertical spacing while maintaining Sv/Tult ratio led to a more uniform distribution of horizontal displacements along the facing wall and a substantial reduction in relative settlements. This reduction suggests that closely spaced reinforcements effectively mitigate the down-drag effect altering the mechanisms governing connection load development and, consequently, influence the appropriate methodology for calculating required connection loads in design analysis.

Geosynthetics International
Universidade Federal de São Carlos (BR), Universidade Federal de São Paulo (BR)
Sustainable cities and communities
Openalex Percentile: Top 73%
Geotechnical Engineering and Soil Stabilization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.