Evaluating a ballistocardiography derived respiratory rate algorithm through comprehensive clinical validation across multiple settings

Continuous respiratory rate (RR) monitoring is key for early deterioration detection, but conventional methods require contact. Ballistocardiography (BCG) offers an unobtrusive alternative using an under-mattress sensor. This study evaluated a BCG-based RR algorithm across diverse clinical settings and populations. BCG data from 11 studies involving 400 subjects across wards, ICUs, sleep labs, and healthy volunteers were analyzed. Reference RR was measured using capnography or polysomnography. An algorithm processed BCG signals via filtering,, dynamic thresholding, and median filtering to estimate RR. Performance was assessed by mean absolute error (MAE), detection rate (DR), and agreement with reference using Bland-Altman, Deming regression, and Pearson’s coefficient. Across 68,342 reference datapoints the algorithm achieved an MAE of 1.29 BrPM and a 92.68% detection rate. Performance was consistent across studies, with MAE ranging from 0.96 to 1.8 BrPM and detection rates from 85 to 97%. Accuracy was higher in controlled settings (e.g., sleep lab: MAE − 0.96 BrPM, 95.8% detection) and slightly lower in wards (MAE ~ 1.6 BrPM, 86–93% detection). Subgroup analyses by geography, demographics, and comorbidities showed consistently low error and good detection, except in COPD patients, where detection dropped to ~ 78% (MAE-1.3 BrPM). Bland–Altman and Deming regression showed minimal bias (–0.39 BrPM) and strong correlation (Pearson’s r = 0.86). A continuous, unobtrusive BCG-based RR measure offers high accuracy and detection, supporting its use in early respiratory event detection and improved patient care.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-30
DOI
https://doi.org/10.1038/s41598-025-33325-8
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating a ballistocardiography derived respiratory rate algorithm through comprehensive clinical validation across multiple settings

Inam Ur Rahman, Kumar Chokalingam, Yogesh Kothari, Gaurav Parchani et al.
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Evaluating a ballistocardiography derived respiratory rate algorithm through comprehensive clinical validation across multiple settings

Inam Ur Rahman, Kumar Chokalingam, Yogesh Kothari, Gaurav Parchani, Ashwathi Nambiar, Kunal Sarkar, Siva Bhavana, Ashish Kaushal, Muthukumarasamy Saravanan, Mudit Dandwate, Ravi Mahajan
article en

Abstract

Continuous respiratory rate (RR) monitoring is key for early deterioration detection, but conventional methods require contact. Ballistocardiography (BCG) offers an unobtrusive alternative using an under-mattress sensor. This study evaluated a BCG-based RR algorithm across diverse clinical settings and populations. BCG data from 11 studies involving 400 subjects across wards, ICUs, sleep labs, and healthy volunteers were analyzed. Reference RR was measured using capnography or polysomnography. An algorithm processed BCG signals via filtering,, dynamic thresholding, and median filtering to estimate RR. Performance was assessed by mean absolute error (MAE), detection rate (DR), and agreement with reference using Bland-Altman, Deming regression, and Pearson’s coefficient. Across 68,342 reference datapoints the algorithm achieved an MAE of 1.29 BrPM and a 92.68% detection rate. Performance was consistent across studies, with MAE ranging from 0.96 to 1.8 BrPM and detection rates from 85 to 97%. Accuracy was higher in controlled settings (e.g., sleep lab: MAE − 0.96 BrPM, 95.8% detection) and slightly lower in wards (MAE ~ 1.6 BrPM, 86–93% detection). Subgroup analyses by geography, demographics, and comorbidities showed consistently low error and good detection, except in COPD patients, where detection dropped to ~ 78% (MAE-1.3 BrPM). Bland–Altman and Deming regression showed minimal bias (–0.39 BrPM) and strong correlation (Pearson’s r = 0.86). A continuous, unobtrusive BCG-based RR measure offers high accuracy and detection, supporting its use in early respiratory event detection and improved patient care.

Scientific ReportsVol. 16(1)
Bangalore Diabetes Centre (IN)
Good health and well-being
Openalex Percentile: Top 73%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating a ballistocardiography derived respiratory rate algorithm through comprehensive clinical validation across multiple settings — Inam Ur Rahman, Kumar Chokalingam, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS