Discussion of the Turbulent Swirling Flow Field in the Residential Ventilation Systems with Axial Fans

Axial fans are widely used in local and decentralized residential ventilation applications, such as bathroom and toilet exhausts and short-duct ventilation systems, but the turbulent swirling flow they generate can lead to increased hydraulic losses, reduced energy efficiency, and unstable fan operation. This study experimentally investigates the swirling flow produced by the axial fan operating in a straight duct, following the ISO 5801, case B. Original classical probes and one-component laser Doppler anemometry (LDA) were used to measure velocity components at multiple downstream locations. Results show a strong forced-vortex core (i.e., solid body profile) and a highly non-uniform axial velocity profile near the impeller (x/D = 3.35), which homogenizes downstream (x/D = 26.31), indicating significant energy loss. Circulation and swirl number decrease significantly downstream, but residual swirl remains throughout the duct, increasing pressure drops and leading to unstable fan performance. These findings demonstrate that swirl-induced velocity-profile transformations are a major source of inefficiency in residential ventilation systems employing axial fans without flow-straightening devices.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-01-30
DOI
https://doi.org/10.3390/pr14030494
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Discussion of the Turbulent Swirling Flow Field in the Residential Ventilation Systems with Axial Fans

Irina Miodragovic Vella, Čantrak Đorđe S., Slobodan Tašin, Vesna Mila Čolić-Damjanović
Processes
Infection Control and Ventilation
article

Discussion of the Turbulent Swirling Flow Field in the Residential Ventilation Systems with Axial Fans

Irina Miodragovic Vella, Čantrak Đorđe S., Slobodan Tašin, Vesna Mila Čolić-Damjanović
article en

Abstract

Axial fans are widely used in local and decentralized residential ventilation applications, such as bathroom and toilet exhausts and short-duct ventilation systems, but the turbulent swirling flow they generate can lead to increased hydraulic losses, reduced energy efficiency, and unstable fan operation. This study experimentally investigates the swirling flow produced by the axial fan operating in a straight duct, following the ISO 5801, case B. Original classical probes and one-component laser Doppler anemometry (LDA) were used to measure velocity components at multiple downstream locations. Results show a strong forced-vortex core (i.e., solid body profile) and a highly non-uniform axial velocity profile near the impeller (x/D = 3.35), which homogenizes downstream (x/D = 26.31), indicating significant energy loss. Circulation and swirl number decrease significantly downstream, but residual swirl remains throughout the duct, increasing pressure drops and leading to unstable fan performance. These findings demonstrate that swirl-induced velocity-profile transformations are a major source of inefficiency in residential ventilation systems employing axial fans without flow-straightening devices.

ProcessesVol. 14(3)
University of Novi Sad (RS), University of Malta (MT), University of Belgrade (RS)
Affordable and clean energy
Openalex Percentile: Top 73%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.