ASSESSMENT OF BACKGROUND RADIATION LEVELS AT THE RADIOLOGY DEPARTMENT OF A TERTIARY HOSPITAL IN NORTH-CENTRAL NIGERIA

Background: Background radiation has over the years become a public health concern. It is therefore, imperative to ascertain its levels within strategic areas in our radiology facility for monitoring and compliance with international standards. Objectives: To determine the background radiation levels in the Radiology Department of Federal Medical Centre (FMC), Keffi, Nigeria. Methodology: The design was prospective and cross-sectional and involved the measurement of background radiation levels at various locations in the radiology department. Calibrated thermo Scientific RadEye TM B20 / B20-ER survey meter, an associated scalar counter, and a stopwatch, were used for measurements at each point, based on standard guidelines recommended by the International Atomic Energy Agency (IAEA). Results: The least mean radiation (0.11µSv/hr) was detected in the computed tomography (CT) suite while the maximum value (0.13µSv/hr) emanated from the radiographers' common room. The coefficient of variation for the Chief Radiographers office, Head of Department's office and the Radiologist’s office were similar 8.3%. The radiographers’ common room was slightly higher (10.9%). The main diagnostic room and seminar room had 16.7%, while it was 9.09% for the CT suite. The standard error ranged between 0.002 and 0.004. There was statistically significant difference in all test values at a level of significance of 5% (p < 0.05). Conclusion: Background radiation values obtained were within recommended standards. However, there is need for regular radiation monitoring as part of radiation safety culture in our radiology facility.

Authors

Institutions

Publication Details

Journal
JRRS
Published
2026-01-12
DOI
https://doi.org/10.82547/jrrs.vol29no1.104
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ASSESSMENT OF BACKGROUND RADIATION LEVELS AT THE RADIOLOGY DEPARTMENT OF A TERTIARY HOSPITAL IN NORTH-CENTRAL NIGERIA

Joseph Dlama Zira, Abdullahi A. Mundi, Eshiett Peter, Kpaku Goriya et al.
JRRS
Radiation Dose and Imaging
article

ASSESSMENT OF BACKGROUND RADIATION LEVELS AT THE RADIOLOGY DEPARTMENT OF A TERTIARY HOSPITAL IN NORTH-CENTRAL NIGERIA

Joseph Dlama Zira, Abdullahi A. Mundi, Eshiett Peter, Kpaku Goriya, Matthew Abubakar, Egga Anita
article en

Abstract

Background: Background radiation has over the years become a public health concern. It is therefore, imperative to ascertain its levels within strategic areas in our radiology facility for monitoring and compliance with international standards. Objectives: To determine the background radiation levels in the Radiology Department of Federal Medical Centre (FMC), Keffi, Nigeria. Methodology: The design was prospective and cross-sectional and involved the measurement of background radiation levels at various locations in the radiology department. Calibrated thermo Scientific RadEye TM B20 / B20-ER survey meter, an associated scalar counter, and a stopwatch, were used for measurements at each point, based on standard guidelines recommended by the International Atomic Energy Agency (IAEA). Results: The least mean radiation (0.11µSv/hr) was detected in the computed tomography (CT) suite while the maximum value (0.13µSv/hr) emanated from the radiographers' common room. The coefficient of variation for the Chief Radiographers office, Head of Department's office and the Radiologist’s office were similar 8.3%. The radiographers’ common room was slightly higher (10.9%). The main diagnostic room and seminar room had 16.7%, while it was 9.09% for the CT suite. The standard error ranged between 0.002 and 0.004. There was statistically significant difference in all test values at a level of significance of 5% (p < 0.05). Conclusion: Background radiation values obtained were within recommended standards. However, there is need for regular radiation monitoring as part of radiation safety culture in our radiology facility.

JRRS
Abubakar Tafawa Balewa University (NG), Nasarawa State University (NG), National Space Research and Development Agency (NG), Federal Medical Centre (NG), University of Maiduguri (NG)
Affordable and clean energy
Openalex Percentile: Top 73%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.