μGRAPHILINE: Performance of an automatic combustion and graphitization system

Abstract Radiocarbon dating by accelerator mass spectrometry (AMS) requires transforming samples into graphite, a step that typically depends on liquid nitrogen and high-purity carrier gases, increasing both cost and operational complexity. We present μGRAPHILINE, a fully automated, modular combustion–graphitization line that removes these dependencies by combining dual-zone combustion with iron–zinc reduction. Performance was evaluated on more than 180 standards and reference materials targets measured on two independent AMS systems. The μGRAPHILINE consistently achieved >90% graphitization yields, stable backgrounds of ∼0.24 pMC (≈48,500 BP), and sample throughput of ∼3.5 hours per target. Reliable operation was demonstrated for a broad sample-size range, from routine 1 mg C down to ∼0.2 mg C, with ion currents sufficient for precise AMS analysis. The system’s automation, modularity, and low memory effect support improved laboratory throughput and operator efficiency. These results indicate that μGRAPHILINE provides a robust and efficient approach to radiocarbon sample preparation with broad potential applications.

Authors

Institutions

Publication Details

Journal
Radiocarbon
Published
2026-01-30
DOI
https://doi.org/10.1017/rdc.2025.10180
Primary Topic
Archaeology and ancient environmental studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

μGRAPHILINE: Performance of an automatic combustion and graphitization system

Aleksander Kolarczyk, Konrad Tudyka, Alicja Ustrzycka, Maksymilian Jędrzejowski et al.
Radiocarbon
Archaeology and ancient environmental studies
article

μGRAPHILINE: Performance of an automatic combustion and graphitization system

Aleksander Kolarczyk, Konrad Tudyka, Alicja Ustrzycka, Maksymilian Jędrzejowski, Sławomira Pawełczyk, Andrzej Rakowski, Kacper Kłosok, Maciej Gosek
article en

Abstract

Abstract Radiocarbon dating by accelerator mass spectrometry (AMS) requires transforming samples into graphite, a step that typically depends on liquid nitrogen and high-purity carrier gases, increasing both cost and operational complexity. We present μGRAPHILINE, a fully automated, modular combustion–graphitization line that removes these dependencies by combining dual-zone combustion with iron–zinc reduction. Performance was evaluated on more than 180 standards and reference materials targets measured on two independent AMS systems. The μGRAPHILINE consistently achieved >90% graphitization yields, stable backgrounds of ∼0.24 pMC (≈48,500 BP), and sample throughput of ∼3.5 hours per target. Reliable operation was demonstrated for a broad sample-size range, from routine 1 mg C down to ∼0.2 mg C, with ion currents sufficient for precise AMS analysis. The system’s automation, modularity, and low memory effect support improved laboratory throughput and operator efficiency. These results indicate that μGRAPHILINE provides a robust and efficient approach to radiocarbon sample preparation with broad potential applications.

Radiocarbon
Silesian University of Technology (PL), Ta Solutions (China) (CN), FZU ‒ Institute of Physics of the Academy of Sciences of the Czech Republic (CZ)
Narodowym Centrum Nauki, Silesian University of Technology
Affordable and clean energy
Openalex Percentile: Top 84%
Archaeology and ancient environmental studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.