Comparison of the endoscopic surgical monitoring system and blood parameters for evaluating irrigation fluid absorption during bipolar plasmakinetic transurethral resection of the prostate: a prospective observational study

Irrigation fluid absorption is an unpredictable complication during transurethral resection of the prostate (TURP). This prospective study aimed to compare the Endoscopic Surgical Monitoring System (ESMS) and blood parameters for evaluating fluid absorption volume in patients undergoing bipolar plasmakinetic TURP. Bipolar TURP was performed using 0.9% saline for bladder irrigation. The ESMS measured fluid absorption volumes in real time. In addition, arterial blood samples were collected for blood gas analysis immediately before irrigation and after surgery, with the absorption volume calculated using equations based on changes in plasma sodium, chloride, potassium, calcium, and hemoglobin concentrations. A total of 420 patients (mean age 69.8 ± 7.7 years) were included. All calculated volumes based on blood parameters were higher than the ESMS-measured volume. The volume calculated from plasma chloride concentration changes showed the closest agreement with the ESMS volume (867.5 ± 748.9 vs. 843.3 ± 722.1 mL, P = 0.416), with a mean bias of 14.4 mL and 95% agreement limits of -385.7 to 414.5 mL. Regression analysis demonstrated a strong linear relationship between plasma chloride elevation and actual absorption volumes (R²=0.776, P = 0.001). However, further analysis revealed a mean percentage bias of + 19%, indicating a systematic overestimation tendency in blood chloride method. Furthermore, a clinically significant discrepancy (> 300 mL) between the blood chloride method and ESMS was associated with altered clinical management, including increased diuretic use (36.7% vs. 15.0%, P < 0.001) and limitation of intravenous fluids (33.3% vs. 17.5%, P = 0.004). Among the blood parameters, plasma chloride provides the most accurate estimation of irrigation fluid absorption and can serve as a practical hematologic indicator when ESMS is unavailable. However, clinicians should be aware of its inherent overestimation tendency and the potential for clinically significant discrepancies to impact patient management. This study was prospectively registered in the Chinese Clinical Trial Registry on December 25, 2023 (www.chictr.org.cn; Registration Number: ChiCTR2300079095).

Authors

Institutions

Publication Details

Journal
BMC Anesthesiology
Published
2026-01-30
DOI
https://doi.org/10.1186/s12871-026-03652-y
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the endoscopic surgical monitoring system and blood parameters for evaluating irrigation fluid absorption during bipolar plasmakinetic transurethral resection of the prostate: a prospective observational study

Jun Mi, Jiangtao Bai, LuYang Zhang, Guilin Wang et al.
BMC Anesthesiology
Urinary Bladder and Prostate Research
article

Comparison of the endoscopic surgical monitoring system and blood parameters for evaluating irrigation fluid absorption during bipolar plasmakinetic transurethral resection of the prostate: a prospective observational study

Jun Mi, Jiangtao Bai, LuYang Zhang, Guilin Wang, Yunxin Zhang, Jin Qi, Haitao Jia, Ting Guo, Qihui Zheng, Zhilong Dong, Junqiang Tian, Li Yang, Zhiping Wang
article en

Abstract

Irrigation fluid absorption is an unpredictable complication during transurethral resection of the prostate (TURP). This prospective study aimed to compare the Endoscopic Surgical Monitoring System (ESMS) and blood parameters for evaluating fluid absorption volume in patients undergoing bipolar plasmakinetic TURP. Bipolar TURP was performed using 0.9% saline for bladder irrigation. The ESMS measured fluid absorption volumes in real time. In addition, arterial blood samples were collected for blood gas analysis immediately before irrigation and after surgery, with the absorption volume calculated using equations based on changes in plasma sodium, chloride, potassium, calcium, and hemoglobin concentrations. A total of 420 patients (mean age 69.8 ± 7.7 years) were included. All calculated volumes based on blood parameters were higher than the ESMS-measured volume. The volume calculated from plasma chloride concentration changes showed the closest agreement with the ESMS volume (867.5 ± 748.9 vs. 843.3 ± 722.1 mL, P = 0.416), with a mean bias of 14.4 mL and 95% agreement limits of -385.7 to 414.5 mL. Regression analysis demonstrated a strong linear relationship between plasma chloride elevation and actual absorption volumes (R²=0.776, P = 0.001). However, further analysis revealed a mean percentage bias of + 19%, indicating a systematic overestimation tendency in blood chloride method. Furthermore, a clinically significant discrepancy (> 300 mL) between the blood chloride method and ESMS was associated with altered clinical management, including increased diuretic use (36.7% vs. 15.0%, P < 0.001) and limitation of intravenous fluids (33.3% vs. 17.5%, P = 0.004). Among the blood parameters, plasma chloride provides the most accurate estimation of irrigation fluid absorption and can serve as a practical hematologic indicator when ESMS is unavailable. However, clinicians should be aware of its inherent overestimation tendency and the potential for clinically significant discrepancies to impact patient management. This study was prospectively registered in the Chinese Clinical Trial Registry on December 25, 2023 (www.chictr.org.cn; Registration Number: ChiCTR2300079095).

BMC AnesthesiologyVol. 26(1)
Gansu Agricultural University (CN), Lanzhou University Second Hospital (CN), Gansu Institute of Political Science and Law (CN), Lanzhou University (CN)
Clean water and sanitation
Openalex Percentile: Top 74%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.