Development of the muon beam monitor for COMET experiment using SiC detector

The COMET Experiment aims to search for the muon-to-electron (\(\mu-e\)) conversion process, one of the lepton flavour violation processes, with a target single event sensitivity of \(\mathcal{O}(10^{-17})\). In COMET Phase-I, the muon beam monitor (MBM) using silicon carbide (SiC) detectors, jointly developed by KEK and AIST, will be installed to suppress background events caused by beam instability and enable detailed beam control. To confirm the response of the SiC detector to a pulsed muon beam, a beam test was conducted in J-PARC MLF in June 2024. As a result of the analysis, the muon signals were clearly observed, and sufficient linearity up to 35 incident muons was confirmed. For practical installation, the position of the SiC MBM was reconsidered. The downstream placement of the primary detector system was investigated with considerations of maintainability and scheduling. Simulation studies confirmed that the beam profile can be obtained even downstream and that by adjusting the sampling timing, the muon profile can be reasonably well reproduced.

Authors

Publication Details

Published
2026-01-30
DOI
https://doi.org/10.22323/1.485.0542
Primary Topic
Neutrino Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of the muon beam monitor for COMET experiment using SiC detector

Satoshi MIHARA, Y. Fukao, Kenya Okabe, M. Shoji et al.
Neutrino Physics Research
article

Development of the muon beam monitor for COMET experiment using SiC detector

Satoshi MIHARA, Y. Fukao, Kenya Okabe, M. Shoji, Ryoji Kosugi, Kazutoshi Kojima, Tetsuichi KISHISHITA, Yowichi Fujita, Youichi Igarashi, Yoshiki Yamaguchi, Hajime Nishiguchi, Yasunori Tanaka
article en

Abstract

The COMET Experiment aims to search for the muon-to-electron (\(\mu-e\)) conversion process, one of the lepton flavour violation processes, with a target single event sensitivity of \(\mathcal{O}(10^{-17})\). In COMET Phase-I, the muon beam monitor (MBM) using silicon carbide (SiC) detectors, jointly developed by KEK and AIST, will be installed to suppress background events caused by beam instability and enable detailed beam control. To confirm the response of the SiC detector to a pulsed muon beam, a beam test was conducted in J-PARC MLF in June 2024. As a result of the analysis, the muon signals were clearly observed, and sufficient linearity up to 35 incident muons was confirmed. For practical installation, the position of the SiC MBM was reconsidered. The downstream placement of the primary detector system was investigated with considerations of maintainability and scheduling. Simulation studies confirmed that the beam profile can be obtained even downstream and that by adjusting the sampling timing, the muon profile can be reasonably well reproduced.

Japan Society for the Promotion of Science
Openalex Percentile: Top 69%
Neutrino Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.