Evaluation of Copper Incorporation into Titanium via Ion Plating Diversified: Morphological, Structural, and Preliminary Biological Assessment

Surface contamination of titanium-based implants by microorganisms remains a major clinical challenge. In this study, grade 1 titanium substrates were modified by low-energy ion plating diversified (IPD) with copper ions at 3 keV and 7 keV to evaluate their morphological, structural, and preliminary biological behavior. Characterization by SEM, EDS, and XRF confirmed homogeneous copper incorporation, with similar concentrations (∼0.3 wt %) for both energies. SRIM simulations indicated Gaussian implantation profiles with peak concentrations at 4 nm and 6 nm below the surface, respectively. Salt spray testing showed that copper implantation did not impair the corrosion resistance of titanium. However, biological assays using <i>Staphylococcus aureus</i> revealed no inhibitory halos or significant cell death, indicating that copper ions implanted at these energies do not reach the surface or diffuse into the medium. These findings define the physical limitations of low-energy IPD for antimicrobial surface design, providing helpful guidance for future process optimization.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-01-30
DOI
https://doi.org/10.1021/acsomega.5c09662
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Copper Incorporation into Titanium via Ion Plating Diversified: Morphological, Structural, and Preliminary Biological Assessment

Camila Baldasso, César Aguzzoli, Wendel Paulo Silvestre, Eduardo Antônio Zanella
ACS Omega
Metal and Thin Film Mechanics
article

Evaluation of Copper Incorporation into Titanium via Ion Plating Diversified: Morphological, Structural, and Preliminary Biological Assessment

Camila Baldasso, César Aguzzoli, Wendel Paulo Silvestre, Eduardo Antônio Zanella
article en

Abstract

Surface contamination of titanium-based implants by microorganisms remains a major clinical challenge. In this study, grade 1 titanium substrates were modified by low-energy ion plating diversified (IPD) with copper ions at 3 keV and 7 keV to evaluate their morphological, structural, and preliminary biological behavior. Characterization by SEM, EDS, and XRF confirmed homogeneous copper incorporation, with similar concentrations (∼0.3 wt %) for both energies. SRIM simulations indicated Gaussian implantation profiles with peak concentrations at 4 nm and 6 nm below the surface, respectively. Salt spray testing showed that copper implantation did not impair the corrosion resistance of titanium. However, biological assays using <i>Staphylococcus aureus</i> revealed no inhibitory halos or significant cell death, indicating that copper ions implanted at these energies do not reach the surface or diffuse into the medium. These findings define the physical limitations of low-energy IPD for antimicrobial surface design, providing helpful guidance for future process optimization.

ACS OmegaVol. 11(6)
Universidade de Caxias do Sul (BR), Institute for Postgraduate Medical Education (CZ)
Affordable and clean energy
Openalex Percentile: Top 72%
Metal and Thin Film Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.