AN ASSESSMENT OF THE LEAD RUBBER APRONS IN RADIODIAGNOSTIC CENTRES IN SOUTH-SOUTH NIGERIA

Background of Study: Radiation protection is of core importance in radiodiagnostic centres, to keep both patients care givers and staff of the centres from stochastic and non- stochastic effects of radiation. The effectiveness and protectiveness of aprons are of valuable importance, it is therefore necessary to assess these aprons to ensure efficacy. Such quality checks have not been reported in the South – South region of Nigeria. Method: Twenty two protective lead aprons from 18 radiological clinics in South-South Nigeria were directly exposed to X-rays with average factors of 70 ± 5kVp, 16 mAs and 100 cm Source to apron distance, with 43 x 35 cm cassettes places underneath to cover the upper (thoracic half) and the lower (abdominal half) respectively. Exposed films were processed in each centre following regular processing protocols to obtain radiographs with images of the state of the aprons. The images were analyzed on the basis of each apron’s lead equivalence (content), age, brand and the type of defects observed. Defects were characterized into cracks, tears, splits and rips. Results: Results showed that 68% of all the aprons under study were defective, having cracks (44%), tears (33%), splits (15%) and/or rips (8%). About 73 % of the defective aprons had more than one (1) type of defect. Conclusion: Over two-thirds (⅔) of lead aprons found in diagnostic radiology centres in South – South Nigeria, have shown sufficient evidence of defects to suggest that they may not be useful for radiation protection of the users.

Authors

Institutions

Publication Details

Journal
JRRS
Published
2026-01-28
DOI
https://doi.org/10.82547/jrrs.vol24no1.124
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AN ASSESSMENT OF THE LEAD RUBBER APRONS IN RADIODIAGNOSTIC CENTRES IN SOUTH-SOUTH NIGERIA

E. Esien-Umo, D. U. Eduwem, E. V. Ukpong, I. Efanga et al.
JRRS
Radiation Dose and Imaging
article

AN ASSESSMENT OF THE LEAD RUBBER APRONS IN RADIODIAGNOSTIC CENTRES IN SOUTH-SOUTH NIGERIA

E. Esien-Umo, D. U. Eduwem, E. V. Ukpong, I. Efanga, N. A. James
article en

Abstract

Background of Study: Radiation protection is of core importance in radiodiagnostic centres, to keep both patients care givers and staff of the centres from stochastic and non- stochastic effects of radiation. The effectiveness and protectiveness of aprons are of valuable importance, it is therefore necessary to assess these aprons to ensure efficacy. Such quality checks have not been reported in the South – South region of Nigeria. Method: Twenty two protective lead aprons from 18 radiological clinics in South-South Nigeria were directly exposed to X-rays with average factors of 70 ± 5kVp, 16 mAs and 100 cm Source to apron distance, with 43 x 35 cm cassettes places underneath to cover the upper (thoracic half) and the lower (abdominal half) respectively. Exposed films were processed in each centre following regular processing protocols to obtain radiographs with images of the state of the aprons. The images were analyzed on the basis of each apron’s lead equivalence (content), age, brand and the type of defects observed. Defects were characterized into cracks, tears, splits and rips. Results: Results showed that 68% of all the aprons under study were defective, having cracks (44%), tears (33%), splits (15%) and/or rips (8%). About 73 % of the defective aprons had more than one (1) type of defect. Conclusion: Over two-thirds (⅔) of lead aprons found in diagnostic radiology centres in South – South Nigeria, have shown sufficient evidence of defects to suggest that they may not be useful for radiation protection of the users.

JRRS
University of Calabar (NG)
Openalex Percentile: Top 73%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.