Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators

ABSTRACT A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.

Authors

Institutions

Publication Details

Journal
Earthquake Engineering & Structural Dynamics
Published
2026-01-28
DOI
https://doi.org/10.1002/eqe.70132
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators

Kiran Rangwani, Geoffrey W. Rodgers, Zheng Luo, Shahab Ramhormozian et al.
Earthquake Engineering & Structural Dynamics
Seismic Performance and Analysis
article

Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators

Kiran Rangwani, Geoffrey W. Rodgers, Zheng Luo, Shahab Ramhormozian, A. Tiwari, H Zhang, Zhenduo Yan, Yudi Zhang, LiangJiu Jia, Rajesh Dhakal, Xianzhong Zha, Ping Xiang, Pierre Quenneville, Yuao Lin, Gregory A. MacRae, Wenhao Sun, Charles Clifton, Rajesh Shrestha
article en

Abstract

ABSTRACT A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.

Earthquake Engineering & Structural Dynamics
Tongji University (CN), University of Auckland (NZ), University of Canterbury (NZ), Auckland University of Technology (NZ)
Sustainable cities and communities
Openalex Percentile: Top 74%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.