Nondestructive, fatigue cyclic, and ramped cyclic biomechanical testing of surgical techniques for stabilization of the lumbosacral junction in dogs

Objective: To compare transarticular screw fixation (TSF), pedicle screw‐rod fixation (PSRF), and screws and polymethylmethacrylate (SPMMA) for stabilization of the canine lumbosacral junction (LSJ). Study design: Ex vivo biomechanical study. Sample population Twenty‐one L7‐S1 canine spine specimens collected from adult, large‐breed dogs. Methods: Specimens were subjected to nondestructive biomechanical testing in flexion/extension (FE), lateral bending (LB), and axial rotation (AR). Subsequently, the L7‐S1 joint was destabilized by dorsal laminectomy and partial discectomy of L7‐S1 and then stabilized by (1) TSF, (2) PSRF, or (3) SPMMA ( n = 7 specimens/group). Stabilized specimens were subjected to nondestructive biomechanical testing, fatigue cyclic testing, and ramped cyclic testing. For nondestructive and fatigue cyclic testing, range of motion (ROM) was calculated for each testing condition/stabilization method, while for ramped cyclic testing the bending moment necessary to reach a ROM of 5.0°, 7.5° and 10.0° and failure mode were recorded. Linear mixed models and Fisher's exact test were used to analyze continuous parameters and failure modes, respectively. Results: All stabilization methods resulted in an equal reduction in ROM in FE. Fatigue cyclic testing resulted in minor increases in ROM compared to baseline for all groups. Ramped cyclic testing resulted in failure of all groups, with no differences between groups for the bending moment necessary to reach 5.0°/7.5°/10.0° of ROM. The main failure mode for each method was progressive screw loosening. Conclusion Transarticular screw fixation, PSRF and SPMMA provided immediate biomechanical stability to the LSJ and were similar when subjected to fatigue and ramped cyclic testing. Clinical significance Transarticular screw fixation, PSRF, and SPMMA are biomechanically effective options for stabilizing the canine LSJ. This study supports clinical use of these procedures.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2026-01-14
DOI
https://doi.org/10.5167/uzh-283307
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nondestructive, fatigue cyclic, and ramped cyclic biomechanical testing of surgical techniques for stabilization of the lumbosacral junction in dogs

Frank Steffen, Raphael Arz, Antonio Pozzi, Lucas Adam Smolders et al.
Universität Zürich, ZORA
Veterinary Orthopedics and Neurology
article

Nondestructive, fatigue cyclic, and ramped cyclic biomechanical testing of surgical techniques for stabilization of the lumbosacral junction in dogs

Frank Steffen, Raphael Arz, Antonio Pozzi, Lucas Adam Smolders, Brian Park
article en

Abstract

Objective: To compare transarticular screw fixation (TSF), pedicle screw‐rod fixation (PSRF), and screws and polymethylmethacrylate (SPMMA) for stabilization of the canine lumbosacral junction (LSJ). Study design: Ex vivo biomechanical study. Sample population Twenty‐one L7‐S1 canine spine specimens collected from adult, large‐breed dogs. Methods: Specimens were subjected to nondestructive biomechanical testing in flexion/extension (FE), lateral bending (LB), and axial rotation (AR). Subsequently, the L7‐S1 joint was destabilized by dorsal laminectomy and partial discectomy of L7‐S1 and then stabilized by (1) TSF, (2) PSRF, or (3) SPMMA ( n = 7 specimens/group). Stabilized specimens were subjected to nondestructive biomechanical testing, fatigue cyclic testing, and ramped cyclic testing. For nondestructive and fatigue cyclic testing, range of motion (ROM) was calculated for each testing condition/stabilization method, while for ramped cyclic testing the bending moment necessary to reach a ROM of 5.0°, 7.5° and 10.0° and failure mode were recorded. Linear mixed models and Fisher's exact test were used to analyze continuous parameters and failure modes, respectively. Results: All stabilization methods resulted in an equal reduction in ROM in FE. Fatigue cyclic testing resulted in minor increases in ROM compared to baseline for all groups. Ramped cyclic testing resulted in failure of all groups, with no differences between groups for the bending moment necessary to reach 5.0°/7.5°/10.0° of ROM. The main failure mode for each method was progressive screw loosening. Conclusion Transarticular screw fixation, PSRF and SPMMA provided immediate biomechanical stability to the LSJ and were similar when subjected to fatigue and ramped cyclic testing. Clinical significance Transarticular screw fixation, PSRF, and SPMMA are biomechanically effective options for stabilizing the canine LSJ. This study supports clinical use of these procedures.

Universität Zürich, ZORA
Openalex Percentile: Top 73%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.