Abstract A028: A Robust and Reproducible Pipeline for Quantifying Stroke Injury in a Heterogeneous, Multi-Site Preclinical Network

Introduction: The failure to translate promising preclinical stroke therapies into clinical success is largely attributed to a lack of rigorous, reproducible outcome measures. While magnetic resonance imaging (MRI) offers a translational alternative to traditional histology, its use in large, multi-site trials is challenged by data heterogeneity and the need for scalable analysis. To address this, we developed and validated a fully automated, open-source image analysis pipeline for the Stroke Preclinical Assessment Network (SPAN), a six-center preclinical trial. Methods: T2 and ADC MRI scans were acquired from 2443 mice and rats (including aged and obese cohorts) at 6 centers 2 and 30 days after middle cerebral artery occlusion (MCAO). Our open-source pipeline performs a complete workflow ( Figure 1 ): 1) preprocessing (image reconstruction, denoising, parameter estimation and quality assessment measures); 2) intensity harmonization to reduce inter-site variability; 3) brain extraction using either traditional rule-based segmentation (rats) or U-net deep learning model (mice); 4) rule-based lesion segmentation via thresholding of harmonized T2 and ADC maps ( Figure 2A-G ); and 5) quantification of midline shift as a proxy for swelling and atrophy ( Figure 3A ). Validation was performed against expert manual tracing on both MRI and 2,3,5-Triphenyltetrazolium chloride (TTC)-stained tissue. Results: The pipeline successfully processed thousands of scans from a heterogeneous collection of scanners. The U-net brain extraction model was highly accurate (Dice score=0.964) and successfully segmented cases where traditional methods failed. Automated lesion volumes correlated strongly with manual expert MRI tracing (R=0.957) and with TTC staining in optimal preparations (R=0.86; Figure 2H ). Harmonization significantly reduced site-specific differences in MRI values. Our geometric midline estimation consistently demonstrated a midline shift towards the contralesional side indicative of swelling on Day 2 and a midline shift towards the ipsilesional side indicative of atrophy on Day 30 ( Figure 3B ). Conclusion: We have developed a validated, end-to-end automated pipeline for quantifying stroke injury in large, multi-site preclinical trials. This work delivers a scalable, objective, and reproducible framework as a shareable, open-source tool that enhances the rigor of preclinical research to help bridge the translational gap in stroke.

Authors

Institutions

Publication Details

Journal
Stroke
Published
2026-01-29
DOI
https://doi.org/10.1161/str.57.suppl_1.a028
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract A028: A Robust and Reproducible Pipeline for Quantifying Stroke Injury in a Heterogeneous, Multi-Site Preclinical Network

Jessica S. Lamb, Patrick Lyden, F Hyder, Erendiz Tarakci et al.
Stroke
Cell Image Analysis Techniques
article

Abstract A028: A Robust and Reproducible Pipeline for Quantifying Stroke Injury in a Heterogeneous, Multi-Site Preclinical Network

Jessica S. Lamb, Patrick Lyden, F Hyder, Erendiz Tarakci, Karisma A. Nagarkatti, Kirsten M. Lynch, Ryan P. Cabeen, Jelena Mihailović, Joseph B. Mandeville, Adnan Bibic, Andreia Morais, Shuning Huang, Marcio Diniz, Basavaraju Sanganahalli, Cenk Ayata, Arthur Toga, Ali Arbab, Daniel Thedens
article en

Abstract

Introduction: The failure to translate promising preclinical stroke therapies into clinical success is largely attributed to a lack of rigorous, reproducible outcome measures. While magnetic resonance imaging (MRI) offers a translational alternative to traditional histology, its use in large, multi-site trials is challenged by data heterogeneity and the need for scalable analysis. To address this, we developed and validated a fully automated, open-source image analysis pipeline for the Stroke Preclinical Assessment Network (SPAN), a six-center preclinical trial. Methods: T2 and ADC MRI scans were acquired from 2443 mice and rats (including aged and obese cohorts) at 6 centers 2 and 30 days after middle cerebral artery occlusion (MCAO). Our open-source pipeline performs a complete workflow ( Figure 1 ): 1) preprocessing (image reconstruction, denoising, parameter estimation and quality assessment measures); 2) intensity harmonization to reduce inter-site variability; 3) brain extraction using either traditional rule-based segmentation (rats) or U-net deep learning model (mice); 4) rule-based lesion segmentation via thresholding of harmonized T2 and ADC maps ( Figure 2A-G ); and 5) quantification of midline shift as a proxy for swelling and atrophy ( Figure 3A ). Validation was performed against expert manual tracing on both MRI and 2,3,5-Triphenyltetrazolium chloride (TTC)-stained tissue. Results: The pipeline successfully processed thousands of scans from a heterogeneous collection of scanners. The U-net brain extraction model was highly accurate (Dice score=0.964) and successfully segmented cases where traditional methods failed. Automated lesion volumes correlated strongly with manual expert MRI tracing (R=0.957) and with TTC staining in optimal preparations (R=0.86; Figure 2H ). Harmonization significantly reduced site-specific differences in MRI values. Our geometric midline estimation consistently demonstrated a midline shift towards the contralesional side indicative of swelling on Day 2 and a midline shift towards the ipsilesional side indicative of atrophy on Day 30 ( Figure 3B ). Conclusion: We have developed a validated, end-to-end automated pipeline for quantifying stroke injury in large, multi-site preclinical trials. This work delivers a scalable, objective, and reproducible framework as a shareable, open-source tool that enhances the rigor of preclinical research to help bridge the translational gap in stroke.

StrokeVol. 57(Suppl_1)
University of Southern California (US), University of Iowa (US), LAC+USC Medical Center (US), Johns Hopkins University (US), Johns Hopkins Medicine (US), Yale University (US), Augusta University Health (US), Massachusetts General Hospital (US), Instrumental Polymer Technologies (United States) (US), The University of Texas Health Science Center (US), Icahn School of Medicine at Mount Sinai (US)
Openalex Percentile: Top 75%
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.