Enhanced degradation of phenol via a zero-valent iron – sodium percarbonate (ZVI-SPC) Fenton-like system: toward environmentally relevant water treatment conditions

This work reports the fundamentals about the performance of a Fenton-like system based on zero-valent iron (ZVI) and sodium percarbonate (SPC), employing phenol (5 – 50 μM) as model contaminant. The influence of operational parameters (pH, temperature, initial SPC concentration, and ZVI amount), as well as the effect of common water constituents and selective scavengers, were systematically studied and compared with the performance of the ZVI-H 2 O 2 treatment. At pH 4.0 and room temperature, the CO 2 * (i.e., CO 2(aq) and the unstable species H 2 CO 3 ) from SPC promoted the corrosion of ZVI, yielding faster phenol oxidation rates with ZVI-SPC than with ZVI-H 2 O 2 . This effect is diminished with acidic conditions or elevated temperatures, due to the lower [CO 2 *] in solution. Regarding the effects of anions and humic acids (investigated as water-matrix components), no appreciable negative effects were observed, except for H 2 PO 4 − that would hinder the process through the formation of insoluble FePO 4(s) and concomitant ZVI passivation. Scavenger experiments revealed that hydroxyl radicals (HO • ) were the predominant reactive species, followed by carbonate radicals (CO 3 •− ). Overall, the ZVI-SPC process demonstrated higher or equal performance than traditional ZVI-H 2 O 2 systems, which warrants further investigations into a promising, low-cost, and safer alternative that could potentially remove emerging contaminants under near-environmental conditions. • A zerovalent iron–sodium percarbonate (ZVI-SPC) Fenton-like system was studied. • ZVI-SPC achieved faster phenol degradation than ZVI–H 2 O 2 under mildly acidic conditions. • Inorganic carbon enhanced ZVI corrosion and iron availability, boosting phenol abatements. • Hydroxyl radicals were the dominant reactive species. • Carbonate radicals played a secondary but significant role.

Authors

Institutions

Publication Details

Journal
Journal of environmental chemical engineering
Published
2026-01-29
DOI
https://doi.org/10.1016/j.jece.2026.121511
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced degradation of phenol via a zero-valent iron – sodium percarbonate (ZVI-SPC) Fenton-like system: toward environmentally relevant water treatment conditions

Iván Sciscenko, Nikolaos Loukoutos, Ioannis A. Katsoyiannis, Marco Minella et al.
Journal of environmental chemical engineering
Advanced oxidation water treatment
article

Enhanced degradation of phenol via a zero-valent iron – sodium percarbonate (ZVI-SPC) Fenton-like system: toward environmentally relevant water treatment conditions

Iván Sciscenko, Nikolaos Loukoutos, Ioannis A. Katsoyiannis, Marco Minella, Davide Vione
article en

Abstract

This work reports the fundamentals about the performance of a Fenton-like system based on zero-valent iron (ZVI) and sodium percarbonate (SPC), employing phenol (5 – 50 μM) as model contaminant. The influence of operational parameters (pH, temperature, initial SPC concentration, and ZVI amount), as well as the effect of common water constituents and selective scavengers, were systematically studied and compared with the performance of the ZVI-H 2 O 2 treatment. At pH 4.0 and room temperature, the CO 2 * (i.e., CO 2(aq) and the unstable species H 2 CO 3 ) from SPC promoted the corrosion of ZVI, yielding faster phenol oxidation rates with ZVI-SPC than with ZVI-H 2 O 2 . This effect is diminished with acidic conditions or elevated temperatures, due to the lower [CO 2 *] in solution. Regarding the effects of anions and humic acids (investigated as water-matrix components), no appreciable negative effects were observed, except for H 2 PO 4 − that would hinder the process through the formation of insoluble FePO 4(s) and concomitant ZVI passivation. Scavenger experiments revealed that hydroxyl radicals (HO • ) were the predominant reactive species, followed by carbonate radicals (CO 3 •− ). Overall, the ZVI-SPC process demonstrated higher or equal performance than traditional ZVI-H 2 O 2 systems, which warrants further investigations into a promising, low-cost, and safer alternative that could potentially remove emerging contaminants under near-environmental conditions. • A zerovalent iron–sodium percarbonate (ZVI-SPC) Fenton-like system was studied. • ZVI-SPC achieved faster phenol degradation than ZVI–H 2 O 2 under mildly acidic conditions. • Inorganic carbon enhanced ZVI corrosion and iron availability, boosting phenol abatements. • Hydroxyl radicals were the dominant reactive species. • Carbonate radicals played a secondary but significant role.

Journal of environmental chemical engineeringVol. 14(2)
Aristotle University of Thessaloniki (GR), University of Turin (IT)
Clean water and sanitation
Openalex Percentile: Top 76%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.