Abstract TP240: Artificial Intelligence Outperforms Radiologists in Detecting Aneurysm Growth

Introduction: Cerebral aneurysm growth is a well-established indicator of instability and rupture risk. Growth is commonly assessed with linear measurements on CT or MR angiography, which may be prone to measurement error and do not account for aneurysm morphology or changes in surface area. We hypothesized that automated measurement using artificial intelligence software would more accurately and precisely detect aneurysm growth. Methods: We conducted a retrospective cohort study of patients with unruptured intracranial aneurysms who underwent serial CTA or MRA imaging from 1/27/2003 to 5/1/2024. De-identified imaging was processed by RAPID Aneurysm (iSchemaView, Menlo Park, CA), a semi-automated AI platform that performs segmentation-based 3D modeling and measures maximum linear dimension (MLD), volume and surface area. Aneurysm size changes were independently assessed in each comparative method by calculating percent change in MLD. Aneurysm growth was based on established criteria, using thresholds that account for measurement error: >10% for aneurysms <2mm, >5% for 2-10mm, and >2% for >10mm. Discrepancies between RAPID and neuroradiologists were adjudicated in an independent and blinded manner by a neurointerventionalist with 12-years of experience, which served as the gold standard. Results: 44 patients with 78 unique aneurysms and 146 total follow-up MLD measurements on serial imaging met inclusion criteria. 33 patients (75%) were female. Median age was 60 (IQR: 47.5-65). Mean and median follow-up intervals were 2.1 and 1.3 years. Aneurysms ranged from 2.93 to 18.15 mm in MLD on RAPID measurements. 28 MLD measurements exhibited growth, RAPID detected 27 of these whereas neuroradiology detected 14. 118 MLD measurements were stable or shrinking, RAPID correctly identified this in 111 measurements versus 112 for neuroradiology. RAPID demonstrated high diagnostic performance, with a sensitivity of 0.96 and specificity of 0.94, compared with neuroradiology, which had a sensitivity of 0.50 and specificity of 0.95. Conclusion: In conclusion, RAPID Aneurysm outperformed neuroradiologists by detecting true linear growth with markedly higher sensitivity while maintaining comparable specificity, demonstrating strong potential to improve longitudinal aneurysm monitoring and may better capture growth dynamics relevant to rupture risk.

Authors

Institutions

Publication Details

Journal
Stroke
Published
2026-01-29
DOI
https://doi.org/10.1161/str.57.suppl_1.tp240
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract TP240: Artificial Intelligence Outperforms Radiologists in Detecting Aneurysm Growth

N Telischak, Sarah J. Snyder, Huy Do, Michael Iv et al.
Stroke
Intracranial Aneurysms: Treatment and Complications
article

Abstract TP240: Artificial Intelligence Outperforms Radiologists in Detecting Aneurysm Growth

N Telischak, Sarah J. Snyder, Huy Do, Michael Iv, Benjamin Pulli, Robert Dodd, Samantha Rhodes, Jeremy J. Heit
article en

Abstract

Introduction: Cerebral aneurysm growth is a well-established indicator of instability and rupture risk. Growth is commonly assessed with linear measurements on CT or MR angiography, which may be prone to measurement error and do not account for aneurysm morphology or changes in surface area. We hypothesized that automated measurement using artificial intelligence software would more accurately and precisely detect aneurysm growth. Methods: We conducted a retrospective cohort study of patients with unruptured intracranial aneurysms who underwent serial CTA or MRA imaging from 1/27/2003 to 5/1/2024. De-identified imaging was processed by RAPID Aneurysm (iSchemaView, Menlo Park, CA), a semi-automated AI platform that performs segmentation-based 3D modeling and measures maximum linear dimension (MLD), volume and surface area. Aneurysm size changes were independently assessed in each comparative method by calculating percent change in MLD. Aneurysm growth was based on established criteria, using thresholds that account for measurement error: >10% for aneurysms <2mm, >5% for 2-10mm, and >2% for >10mm. Discrepancies between RAPID and neuroradiologists were adjudicated in an independent and blinded manner by a neurointerventionalist with 12-years of experience, which served as the gold standard. Results: 44 patients with 78 unique aneurysms and 146 total follow-up MLD measurements on serial imaging met inclusion criteria. 33 patients (75%) were female. Median age was 60 (IQR: 47.5-65). Mean and median follow-up intervals were 2.1 and 1.3 years. Aneurysms ranged from 2.93 to 18.15 mm in MLD on RAPID measurements. 28 MLD measurements exhibited growth, RAPID detected 27 of these whereas neuroradiology detected 14. 118 MLD measurements were stable or shrinking, RAPID correctly identified this in 111 measurements versus 112 for neuroradiology. RAPID demonstrated high diagnostic performance, with a sensitivity of 0.96 and specificity of 0.94, compared with neuroradiology, which had a sensitivity of 0.50 and specificity of 0.95. Conclusion: In conclusion, RAPID Aneurysm outperformed neuroradiologists by detecting true linear growth with markedly higher sensitivity while maintaining comparable specificity, demonstrating strong potential to improve longitudinal aneurysm monitoring and may better capture growth dynamics relevant to rupture risk.

StrokeVol. 57(Suppl_1)
Palo Alto University (US), Stanford Medicine (US), Temple University (US), Stanford University (US)
Openalex Percentile: Top 74%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.