Derivation of equivalent ladder network circuit model for power transformer winding solely from frequency response data and artificial intelligence

Purpose Accurate interpretation of frequency response analysis (FRA) data is crucial for power transformer windings. To address this challenge, this study suggests a new auto-synthesis method to derivate a high-frequency Equivalent Ladder Network Circuit Model (ELNCM) aimed at investigating and interpreting the transformer winding (TRW) characteristics. Design/methodology/approach The precise ELNCM is attained using the transfer function (TF) extracted from the measured FRA data. From where, five winding parameters are recited, mainly, the total ground capacitance Cgeff, the equivalent inductance Leq and capacitance Ceq, the voltage distribution factor α and series capacitance Cs. After that, the precise self and mutual inductances (Ls,Mij) of the proposed ELNCM identification are carried out using artificial intelligence (AI). As the self and mutual inductances cannot be measured directly, this paper presents an AI approach, namely, Logistic Chaotic Archimedes Optimization Algorithm (LCAOA) for improved precision. Findings The physical parameters (Leq,Ceq,Cgeff,α, Cs ) are directly extracted from the FRA data, which is very useful in practical studies. Through the obtained results, actual identification is ensured by faithfully seeing the FRA curves created from TF-AI-ELNCM. Originality/value Going further, unlike previous studies, the proposed method eliminates the need for geometrical data and not necessitate any specific arrangement on the transformer winding. The methodology presented offers substantial practical benefits for transformer winding diagnosis, it eliminates the need for lookup tables or specific configuration models.

Authors

Institutions

Publication Details

Journal
COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering
Published
2026-01-29
DOI
https://doi.org/10.1108/compel-07-2025-0324
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Derivation of equivalent ladder network circuit model for power transformer winding solely from frequency response data and artificial intelligence

Houassine Hamza, Abdallah Chanane
COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering
Power Transformer Diagnostics and Insulation
article

Derivation of equivalent ladder network circuit model for power transformer winding solely from frequency response data and artificial intelligence

Houassine Hamza, Abdallah Chanane
article en

Abstract

Purpose Accurate interpretation of frequency response analysis (FRA) data is crucial for power transformer windings. To address this challenge, this study suggests a new auto-synthesis method to derivate a high-frequency Equivalent Ladder Network Circuit Model (ELNCM) aimed at investigating and interpreting the transformer winding (TRW) characteristics. Design/methodology/approach The precise ELNCM is attained using the transfer function (TF) extracted from the measured FRA data. From where, five winding parameters are recited, mainly, the total ground capacitance Cgeff, the equivalent inductance Leq and capacitance Ceq, the voltage distribution factor α and series capacitance Cs. After that, the precise self and mutual inductances (Ls,Mij) of the proposed ELNCM identification are carried out using artificial intelligence (AI). As the self and mutual inductances cannot be measured directly, this paper presents an AI approach, namely, Logistic Chaotic Archimedes Optimization Algorithm (LCAOA) for improved precision. Findings The physical parameters (Leq,Ceq,Cgeff,α, Cs ) are directly extracted from the FRA data, which is very useful in practical studies. Through the obtained results, actual identification is ensured by faithfully seeing the FRA curves created from TF-AI-ELNCM. Originality/value Going further, unlike previous studies, the proposed method eliminates the need for geometrical data and not necessitate any specific arrangement on the transformer winding. The methodology presented offers substantial practical benefits for transformer winding diagnosis, it eliminates the need for lookup tables or specific configuration models.

COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic EngineeringVol. 45(1)
University of Bouira (DZ), University of Blida (DZ)
Openalex Percentile: Top 73%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.