Electro-optic sampling beam positioning monitor for relativistic electron beams

Non-destructive diagnostics able to resolve transverse offsets and longitudinal separation of ultra-relativistic, two-bunch electron beams are necessary for a variety of applications including the ion channel laser (ICL) and other plasma wakefield (PWFA) experiments. A prototype electro-optic beam positioning monitor (EOS-BPM) utilizing two independent laser pulses traveling through a pair of EO crystals has been installed at the SLAC National Accelerator Laboratory FACET-II facility. This system is capable of order 10 fs temporal resolution and order 100 µm transverse position resolution. To achieve better transverse resolution we introduce a new design using an axicon lens to create a donut beam and a multi-crystal structure placed around the axis of propagation of the electron beam. Experimental results of the prototype EOS-BPM along with the simulated response of the new EOS-BPM design to the ultra-relativistic, two-bunch electron beam used for PWFA experiments at FACET-II will be presented.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-tucn02
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electro-optic sampling beam positioning monitor for relativistic electron beams

Daniel Matteo, Tara Hodgetts, Alexander Knetsch, Brendan O'Shea et al.
JACOW
Laser-Plasma Interactions and Diagnostics
article

Electro-optic sampling beam positioning monitor for relativistic electron beams

Daniel Matteo, Tara Hodgetts, Alexander Knetsch, Brendan O'Shea, Mark Hogan, Gerard Andonian, Robert Ariniello, Valentina Lee, Michael Litos, Elena Ros, Claire Hansel, Shutang Meng
article en

Abstract

Non-destructive diagnostics able to resolve transverse offsets and longitudinal separation of ultra-relativistic, two-bunch electron beams are necessary for a variety of applications including the ion channel laser (ICL) and other plasma wakefield (PWFA) experiments. A prototype electro-optic beam positioning monitor (EOS-BPM) utilizing two independent laser pulses traveling through a pair of EO crystals has been installed at the SLAC National Accelerator Laboratory FACET-II facility. This system is capable of order 10 fs temporal resolution and order 100 µm transverse position resolution. To achieve better transverse resolution we introduce a new design using an axicon lens to create a donut beam and a multi-crystal structure placed around the axis of propagation of the electron beam. Experimental results of the prototype EOS-BPM along with the simulated response of the new EOS-BPM design to the ultra-relativistic, two-bunch electron beam used for PWFA experiments at FACET-II will be presented.

JACOW
Openalex Percentile: Top 70%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.