A stochastic thermo-economic analysis of thermal energy storage for residential cooling: The case of Spain

Electricity use in residential cooling systems has risen considerably in recent years, increasing their share in overall building energy demand and highlighting the need for advanced energy management strategies. Thermal energy storage offers a promising approach because of its operational flexibility and capacity to shift cooling loads to off-peak periods. This study presents a stochastic thermo-economic analysis of integrating cold-water storage tanks as sensible thermal energy storage in residential cooling systems across several climatic conditions in Spain. Three building typologies were assessed: single-family house, apartment mid-rise, and apartment high-rise, considering both air-source and ground-source air conditioning systems. Energy performance was simulated using TRNSYS software, and the results were used to conduct deterministic and stochastic economic assessments based on Monte Carlo simulations. Integrating thermal energy storage in air-source systems achieved electricity savings of up to 14.5% in Seville. In hotter climates, the percentage of energy savings remained nearly constant across building sizes, while in milder climates, smaller buildings showed greater savings. Incorporating thermal energy storage also reduced operational costs by up to 42.3% for the apartment high-rise in Seville owing to load shifting to cheaper electricity periods. Integration in ground-source systems was excluded, as no energy savings were observed. Stochastic analysis showed that the apartment high-rise exhibited better economic performance than the single-family house, with a 19.3% probability of positive net present value compared to 0.5%, while 90% of levelised cost of cold values ranged between 50.9 and 57.7 €/MWh. This underscores, the influence of electricity price dynamics on TES profitability. • Thermo-economic analysis of TES integration in cooling systems in Spain. • Stochastic economic assessment conducted using Monte Carlo simulations. • TES in air-source cooling systems achieved electricity savings of up to 14.5%. • No energy benefit observed for ground-source systems with TES integration. • Feasibility increased for larger buildings and hotter climatic conditions.

Authors

Institutions

Publication Details

Journal
Energy
Published
2026-01-29
DOI
https://doi.org/10.1016/j.energy.2026.140159
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A stochastic thermo-economic analysis of thermal energy storage for residential cooling: The case of Spain

JA Almendros-Ibáñez, M.A. Alfaro-López, J.F. Belmonte, F. Javier Ramírez
Energy
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

A stochastic thermo-economic analysis of thermal energy storage for residential cooling: The case of Spain

JA Almendros-Ibáñez, M.A. Alfaro-López, J.F. Belmonte, F. Javier Ramírez
article en

Abstract

Electricity use in residential cooling systems has risen considerably in recent years, increasing their share in overall building energy demand and highlighting the need for advanced energy management strategies. Thermal energy storage offers a promising approach because of its operational flexibility and capacity to shift cooling loads to off-peak periods. This study presents a stochastic thermo-economic analysis of integrating cold-water storage tanks as sensible thermal energy storage in residential cooling systems across several climatic conditions in Spain. Three building typologies were assessed: single-family house, apartment mid-rise, and apartment high-rise, considering both air-source and ground-source air conditioning systems. Energy performance was simulated using TRNSYS software, and the results were used to conduct deterministic and stochastic economic assessments based on Monte Carlo simulations. Integrating thermal energy storage in air-source systems achieved electricity savings of up to 14.5% in Seville. In hotter climates, the percentage of energy savings remained nearly constant across building sizes, while in milder climates, smaller buildings showed greater savings. Incorporating thermal energy storage also reduced operational costs by up to 42.3% for the apartment high-rise in Seville owing to load shifting to cheaper electricity periods. Integration in ground-source systems was excluded, as no energy savings were observed. Stochastic analysis showed that the apartment high-rise exhibited better economic performance than the single-family house, with a 19.3% probability of positive net present value compared to 0.5%, while 90% of levelised cost of cold values ranged between 50.9 and 57.7 €/MWh. This underscores, the influence of electricity price dynamics on TES profitability. • Thermo-economic analysis of TES integration in cooling systems in Spain. • Stochastic economic assessment conducted using Monte Carlo simulations. • TES in air-source cooling systems achieved electricity savings of up to 14.5%. • No energy benefit observed for ground-source systems with TES integration. • Feasibility increased for larger buildings and hotter climatic conditions.

EnergyVol. 346
University of Castilla-La Mancha (ES)
Affordable and clean energy
Openalex Percentile: Top 73%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.