Computational analysis of mechanical performance for 3D-printed biodegradable PLA cardiovascular stents

Cardiovascular stents are widely applied in the treatment of arterial stenosis, but conventional metallic stents present limitations such as permanent implantation, hypersensitivity reactions, and late restenosis. Biodegradable polymer stents offer a promising alternative, though their translation is restricted by structural design challenges and inadequate mechanical performance. In this study, eight representative stent architectures were computationally evaluated with respect to radial elastic recoil, foreshortening, dogboning, and radial support force. Stents were fabricated from polylactide (PLA) via fused deposition modelling (FDM), and the effects of nozzle temperature, layer height, and printing speed were systematically assessed on PLA dogbone specimens to determine optimised process parameters. Computational analysis revealed that only type B and type F stents met clinical deformation requirements, with radial elastic recoil <6 %, foreshortening <10 %, and dogboning <10 %, while other designs exhibited values exceeding these thresholds. Parallel compression tests further quantified radial support capacity at 50 % compression. Fabrication and dimensional evaluation showed that, although all stent designs could be produced using optimised FDM parameters, manufacturing-induced geometric deviations at thin struts and unit connection regions were unavoidable. As a result, the finite-element simulations should be regarded as providing idealised mechanical responses for comparative design evaluation rather than exact predictions of fabricated prototypes. Overall, these findings provide structural and process design guidelines for the development of mechanically reliable 3D-printed biodegradable PLA cardiovascular stents, while emphasising the importance of manufacturing fidelity when translating computationally optimised designs into physical devices.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2026-01-29
DOI
https://doi.org/10.1016/j.jmbbm.2026.107355
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational analysis of mechanical performance for 3D-printed biodegradable PLA cardiovascular stents

Cian Vyas, Fengyuan Liu, Rixiang Quan, Massimo Caputo et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Coronary Interventions and Diagnostics
article

Computational analysis of mechanical performance for 3D-printed biodegradable PLA cardiovascular stents

Cian Vyas, Fengyuan Liu, Rixiang Quan, Massimo Caputo, Xinmiao Feng, Jialu Li, Giovanni Biglino, Paulo Bartolo, James P.K. Armstrong, Weiting Xu, Yan Xu, Zhipeng Deng, Yi Huang, Xiaolong Chen
article en

Abstract

Cardiovascular stents are widely applied in the treatment of arterial stenosis, but conventional metallic stents present limitations such as permanent implantation, hypersensitivity reactions, and late restenosis. Biodegradable polymer stents offer a promising alternative, though their translation is restricted by structural design challenges and inadequate mechanical performance. In this study, eight representative stent architectures were computationally evaluated with respect to radial elastic recoil, foreshortening, dogboning, and radial support force. Stents were fabricated from polylactide (PLA) via fused deposition modelling (FDM), and the effects of nozzle temperature, layer height, and printing speed were systematically assessed on PLA dogbone specimens to determine optimised process parameters. Computational analysis revealed that only type B and type F stents met clinical deformation requirements, with radial elastic recoil <6 %, foreshortening <10 %, and dogboning <10 %, while other designs exhibited values exceeding these thresholds. Parallel compression tests further quantified radial support capacity at 50 % compression. Fabrication and dimensional evaluation showed that, although all stent designs could be produced using optimised FDM parameters, manufacturing-induced geometric deviations at thin struts and unit connection regions were unavoidable. As a result, the finite-element simulations should be regarded as providing idealised mechanical responses for comparative design evaluation rather than exact predictions of fabricated prototypes. Overall, these findings provide structural and process design guidelines for the development of mechanically reliable 3D-printed biodegradable PLA cardiovascular stents, while emphasising the importance of manufacturing fidelity when translating computationally optimised designs into physical devices.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 176
University of Nottingham (GB), Nanyang Technological University (SG), University of Bristol (GB), City University of Macau (MO)
Openalex Percentile: Top 73%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.