Design and performance analysis of standalone solar photovoltaic power system for health facility in EKET using PVSYST simulation software

In this research, design and performance analysis of standalone solar photovoltaic (SSPV) power system for health facility in Eket using PVSyst simulation software is presented. Specifically, standalone solar photovoltaic (SSPV) power system was designed and simulated with PVsyst for two scenarios for a hospital in Eket Akwa Ibom State. In the first scenario, the SSPV power system was design to eliminate loss off load without any alternative energy source other than the SSPV power system. In the second scenario, the SSPV power system was design to allow for some loss off load giving room for alternative back-up energy source other than the SSPV power system. The case study hospital has daily load demand of 455,754.00 kWh per day which approximates to a 24 hours a day energy consumption of an average load of 18989.75 Watt load. The annual total solar radiation of the site is 1717.2 kWh/m² while the annual mean for the ambient temperature is 24.9°C. The results shows that the scenario 1 has about 7.9% energy output above that of scenario 2. The unused energy in scenario 1 is about 26.5 % higher than that of scenario 2. The energy supply in scenario 2 is about 2% short of the load demand while the scenario 1 has no energy supply shortage. The energy supply shortage in scenario 1 cause the 2 %missing energy or loss of load with the attendant 179 hours of loss of load duration. In all, with detailed loss of load analysis up to hourly level, it is possible to make adequate prior arrangements for managing the expected loss of load incidences.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-12-31
DOI
https://doi.org/10.5281/zenodo.18410325
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance analysis of standalone solar photovoltaic power system for health facility in EKET using PVSYST simulation software

Mbetobong Charles Enoh, Ibiangake Etie Akpan, Dominic David Ekpo, Anyanime Tim UMOETTE
Zenodo (CERN European Organization for Nuclear Research)
Hybrid Renewable Energy Systems
article

Design and performance analysis of standalone solar photovoltaic power system for health facility in EKET using PVSYST simulation software

Mbetobong Charles Enoh, Ibiangake Etie Akpan, Dominic David Ekpo, Anyanime Tim UMOETTE
article en

Abstract

In this research, design and performance analysis of standalone solar photovoltaic (SSPV) power system for health facility in Eket using PVSyst simulation software is presented. Specifically, standalone solar photovoltaic (SSPV) power system was designed and simulated with PVsyst for two scenarios for a hospital in Eket Akwa Ibom State. In the first scenario, the SSPV power system was design to eliminate loss off load without any alternative energy source other than the SSPV power system. In the second scenario, the SSPV power system was design to allow for some loss off load giving room for alternative back-up energy source other than the SSPV power system. The case study hospital has daily load demand of 455,754.00 kWh per day which approximates to a 24 hours a day energy consumption of an average load of 18989.75 Watt load. The annual total solar radiation of the site is 1717.2 kWh/m² while the annual mean for the ambient temperature is 24.9°C. The results shows that the scenario 1 has about 7.9% energy output above that of scenario 2. The unused energy in scenario 1 is about 26.5 % higher than that of scenario 2. The energy supply in scenario 2 is about 2% short of the load demand while the scenario 1 has no energy supply shortage. The energy supply shortage in scenario 1 cause the 2 %missing energy or loss of load with the attendant 179 hours of loss of load duration. In all, with detailed loss of load analysis up to hourly level, it is possible to make adequate prior arrangements for managing the expected loss of load incidences.

Zenodo (CERN European Organization for Nuclear Research)
Akwa Ibom State University (NG)
Affordable and clean energy
Openalex Percentile: Top 40%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.