OCTANE- Oral Cytokine Testing Apparatus for Non-invasive Evaluation

Cytokines such as interleukin-13 (IL-13) and thymic stromal lymphopoietin (TSLP) are pivotal biomarkers in type 2 inflammatory diseases, including asthma and allergic airway disorders. Current cytokine quantification methods are limited by centralized laboratory requirements, large sample volumes, and extended assay times, limiting their utility for point-of-care (POC) diagnostics. Here, we present OCTANE (Oral Cytokine Testing Apparatus for Non-invasive Evaluation), a portable multiplexed electrochemical biosensing platform employing miniaturized HexaPie.m electrodes and non-faradaic electrochemical impedance spectroscopy (nF-EIS) for rapid, label-free detection of IL-13 and TSLP in human saliva. Finite Element Analysis and empirical testing demonstrated that electrode miniaturization enhances sensitivity by increasing baseline impedance and electric field concentration. The OCTANE device integrates automated multiplexing and flexible communication interfaces within a compact form factor, facilitating reliable biomarker quantification with reduced user intervention. The OCTANE device’s performance was rigorously evaluated using calibration curves that demonstrated high linearity and specificity, and spike-and-recovery assays that confirm accurate quantification in complex saliva matrices. Comparative testing with benchtop potentiostats yielded a strong correlation (R 2 > 0.98) and negligible bias, validating the analytical precision of the OCTANE device. The modular design of the OCTANE device further enables adaptability to diverse biomarker panels, positioning it as a next-generation tool for point-of-care immunodiagnostics. • Designed OCTANE , a compact, portable electrochemical biosensing platform. • Features HexaPie.m miniaturized electrodes with reduced saliva volume needs. • Integrates automated multiplexing for six independent electrode readouts. • Provides robust, reproducible nF-EIS performance in modular hardware design. • Shows R 2 > 0.98 correlation and Bland–Altman agreement with benchtop systems.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2026-01-29
DOI
https://doi.org/10.1016/j.biosx.2026.100746
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OCTANE- Oral Cytokine Testing Apparatus for Non-invasive Evaluation

Crisvin Sajee Kadambathil, Nathan Kodjo Mintah Churcher, Vikram Narayanan Dhamu, Shalini Prasad et al.
Biosensors and Bioelectronics X
Advanced Biosensing Techniques and Applications
article

OCTANE- Oral Cytokine Testing Apparatus for Non-invasive Evaluation

Crisvin Sajee Kadambathil, Nathan Kodjo Mintah Churcher, Vikram Narayanan Dhamu, Shalini Prasad, Fatima Zia Rizvi, Sasya Madhurantakam, Salsabil Aziz
article en

Abstract

Cytokines such as interleukin-13 (IL-13) and thymic stromal lymphopoietin (TSLP) are pivotal biomarkers in type 2 inflammatory diseases, including asthma and allergic airway disorders. Current cytokine quantification methods are limited by centralized laboratory requirements, large sample volumes, and extended assay times, limiting their utility for point-of-care (POC) diagnostics. Here, we present OCTANE (Oral Cytokine Testing Apparatus for Non-invasive Evaluation), a portable multiplexed electrochemical biosensing platform employing miniaturized HexaPie.m electrodes and non-faradaic electrochemical impedance spectroscopy (nF-EIS) for rapid, label-free detection of IL-13 and TSLP in human saliva. Finite Element Analysis and empirical testing demonstrated that electrode miniaturization enhances sensitivity by increasing baseline impedance and electric field concentration. The OCTANE device integrates automated multiplexing and flexible communication interfaces within a compact form factor, facilitating reliable biomarker quantification with reduced user intervention. The OCTANE device’s performance was rigorously evaluated using calibration curves that demonstrated high linearity and specificity, and spike-and-recovery assays that confirm accurate quantification in complex saliva matrices. Comparative testing with benchtop potentiostats yielded a strong correlation (R 2 > 0.98) and negligible bias, validating the analytical precision of the OCTANE device. The modular design of the OCTANE device further enables adaptability to diverse biomarker panels, positioning it as a next-generation tool for point-of-care immunodiagnostics. • Designed OCTANE , a compact, portable electrochemical biosensing platform. • Features HexaPie.m miniaturized electrodes with reduced saliva volume needs. • Integrates automated multiplexing for six independent electrode readouts. • Provides robust, reproducible nF-EIS performance in modular hardware design. • Shows R 2 > 0.98 correlation and Bland–Altman agreement with benchtop systems.

Biosensors and Bioelectronics XVol. 29
The University of Texas at Dallas (US)
Openalex Percentile: Top 74%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.