Feasibility analysis of micro-structural ultrasound for scatterer reconstruction in medicine: an in silico study

Although quantitative ultrasound has crossed the threshold from research tool to routine clinical adjunct, current techniques still only interrogate tissue at the millimeter scale. Direct, micrometer-resolved insight into tissue structure, comparable to histology, remains an unmet need. The Scatterer Reconstruction (ScatRec) method, a non-stationary, deconvolution-based technique, shows promise in addressing this need. We improved the ScatRec algorithm and introduced three upgrades to improve its robustness: (i) Anisotropic total-variation, (ii) a Gaussian-noise fidelity term, and (iii) amplitude bound constraints. Additionally we bridge the gap to real work application by utilizing a spatially invariant point spread function. We then evaluated the enhanced reconstruction capabilities using<i>in silico</i>scatterer phantoms. For the first time, we analyzed the resolution limits with several two-scatterer phantoms with different scatterer distances. We tested the reconstruction quality and accuracy with phantoms containing randomly distributed scatterers and a signal-to-noise ratio (SNR) ranging from infinity to 10. Our two-scatterer phantoms showed that our proposed method at 18 MHz has an effective scatterer resolution of 38.5 μm × 156 μm in the axial and lateral directions, respectively, which is 2.6 times better than conventional B-mode. For randomly distributed scatterers, we quantified the reconstruction quality (measured by the normalized correlation coefficient, NCC) and the accuracy (indicated by the relative deviation of the effective acoustic concentration, EAC, compared to the ground truth). Compared to the original ScatRec, the NCC improved 3.7-fold, and the EAC 15.5-fold across realistic SNR of 40. Our feasibility analysis suggests that<i>in vivo</i>micro-structural ultrasound for scatterer reconstruction is within reach, opening a path toward "ultrasonic histology" for diseases that are currently diagnosed only by biopsy.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-01-29
DOI
https://doi.org/10.1088/2057-1976/ae3f37
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility analysis of micro-structural ultrasound for scatterer reconstruction in medicine: an in silico study

Dominik Geisel, Heiko Tzschätzsch, Tom Meyer, Stefan Klemmer Chandía et al.
Biomedical Physics & Engineering Express
Ultrasound Imaging and Elastography
article

Feasibility analysis of micro-structural ultrasound for scatterer reconstruction in medicine: an in silico study

Dominik Geisel, Heiko Tzschätzsch, Tom Meyer, Stefan Klemmer Chandía, Hossein Seyed Aghamiry, Mirjam Colleen Rupinski
article en

Abstract

Although quantitative ultrasound has crossed the threshold from research tool to routine clinical adjunct, current techniques still only interrogate tissue at the millimeter scale. Direct, micrometer-resolved insight into tissue structure, comparable to histology, remains an unmet need. The Scatterer Reconstruction (ScatRec) method, a non-stationary, deconvolution-based technique, shows promise in addressing this need. We improved the ScatRec algorithm and introduced three upgrades to improve its robustness: (i) Anisotropic total-variation, (ii) a Gaussian-noise fidelity term, and (iii) amplitude bound constraints. Additionally we bridge the gap to real work application by utilizing a spatially invariant point spread function. We then evaluated the enhanced reconstruction capabilities using<i>in silico</i>scatterer phantoms. For the first time, we analyzed the resolution limits with several two-scatterer phantoms with different scatterer distances. We tested the reconstruction quality and accuracy with phantoms containing randomly distributed scatterers and a signal-to-noise ratio (SNR) ranging from infinity to 10. Our two-scatterer phantoms showed that our proposed method at 18 MHz has an effective scatterer resolution of 38.5 μm × 156 μm in the axial and lateral directions, respectively, which is 2.6 times better than conventional B-mode. For randomly distributed scatterers, we quantified the reconstruction quality (measured by the normalized correlation coefficient, NCC) and the accuracy (indicated by the relative deviation of the effective acoustic concentration, EAC, compared to the ground truth). Compared to the original ScatRec, the NCC improved 3.7-fold, and the EAC 15.5-fold across realistic SNR of 40. Our feasibility analysis suggests that<i>in vivo</i>micro-structural ultrasound for scatterer reconstruction is within reach, opening a path toward "ultrasonic histology" for diseases that are currently diagnosed only by biopsy.

Biomedical Physics & Engineering ExpressVol. 12(2)
Humboldt-Universität zu Berlin (DE), Freie Universität Berlin (DE), Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 74%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.