Critical limits for early detection of glaucoma, the Uppsala Glaucoma Detection Study (UGDS)

The current study aimed to optimize the measurement design for each quantity of interest, determine critical limits for clinically distinguishing glaucoma-suspect eyes from non-suspect eyes in the UGDS using the optimized design, and compare the efficiency of the measured quantities in estimating sensitivity METHODS: Data from non-glaucoma suspect eyes in the UGDS were analyzed for age and sex dependence, sources of variation, frequency distribution, and assessment of critical limits for glaucoma detection. Critical limit was defined as the extreme 95% confidence limit for the 95% one-sided tolerance. Intraocular pressure (IOP) and visual field contract sensitivity (Mean Deviation, MD), linear cup-to-disc ratio (C/D-linear), neuro-retinal rim area (NRA), nerve fiber layer thickness (cpRNFLT-Global and GDx-TSNIT) were examined RESULTS: Analysis revealed no significant age or sex dependence for the measured quantities. Variability among subjects was found to dominate, affecting the precision of measurements. Frequency distributions approximated normal distributions, enabling the estimation of tolerance limits for critical assessment. The critical limits to distinguish pathological from non-pathological were estimated as 22 mmHg, -3.7 dB, 0.84, 0.6 mm<sup>2</sup>, 56 µm and 33 µm for IOP, MD, C/D-linear, NRA, cpRNFLT-Global and GDx-TSNIT respectively CONCLUSION: It appears preferable to estimate critical limits for small samples using the extreme confidence limit of the tolerance limit. The critical limits obtained here are consistent with previously reported values for the same device models. C/D-linear and NRA-Global metrics estimated with HRT show lower sensitivity-estimation efficiency compared with the other parameters assessed. Individualized intra-patient critical limits require a small increase of the measured quantity to identify glaucoma in the patient who has the disease.

Authors

Institutions

Publication Details

Journal
International Ophthalmology
Published
2026-01-29
DOI
https://doi.org/10.1007/s10792-026-03949-4
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical limits for early detection of glaucoma, the Uppsala Glaucoma Detection Study (UGDS)

Konstancija Kisonaite, Eva Nuija, Zhaohua Yu, Tolga Tumer et al.
International Ophthalmology
Glaucoma and retinal disorders
article

Critical limits for early detection of glaucoma, the Uppsala Glaucoma Detection Study (UGDS)

Konstancija Kisonaite, Eva Nuija, Zhaohua Yu, Tolga Tumer, Albert Alm
article en

Abstract

The current study aimed to optimize the measurement design for each quantity of interest, determine critical limits for clinically distinguishing glaucoma-suspect eyes from non-suspect eyes in the UGDS using the optimized design, and compare the efficiency of the measured quantities in estimating sensitivity METHODS: Data from non-glaucoma suspect eyes in the UGDS were analyzed for age and sex dependence, sources of variation, frequency distribution, and assessment of critical limits for glaucoma detection. Critical limit was defined as the extreme 95% confidence limit for the 95% one-sided tolerance. Intraocular pressure (IOP) and visual field contract sensitivity (Mean Deviation, MD), linear cup-to-disc ratio (C/D-linear), neuro-retinal rim area (NRA), nerve fiber layer thickness (cpRNFLT-Global and GDx-TSNIT) were examined RESULTS: Analysis revealed no significant age or sex dependence for the measured quantities. Variability among subjects was found to dominate, affecting the precision of measurements. Frequency distributions approximated normal distributions, enabling the estimation of tolerance limits for critical assessment. The critical limits to distinguish pathological from non-pathological were estimated as 22 mmHg, -3.7 dB, 0.84, 0.6 mm<sup>2</sup>, 56 µm and 33 µm for IOP, MD, C/D-linear, NRA, cpRNFLT-Global and GDx-TSNIT respectively CONCLUSION: It appears preferable to estimate critical limits for small samples using the extreme confidence limit of the tolerance limit. The critical limits obtained here are consistent with previously reported values for the same device models. C/D-linear and NRA-Global metrics estimated with HRT show lower sensitivity-estimation efficiency compared with the other parameters assessed. Individualized intra-patient critical limits require a small increase of the measured quantity to identify glaucoma in the patient who has the disease.

International OphthalmologyVol. 46(1)
Uppsala University (SE)
Openalex Percentile: Top 74%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.