Autonomous stretchable sensor array with low-power wireless readout for spatial pH mapping

• Stretchable 4 × 4 IrOₓ pH array with super-Nernstian (∼71 mV/pH) sensitivity • Integrated Zn-ion battery and BLE readout for autonomous wireless operation • PDMS-sealed Ag–PDMS vias enable stable pH sensing under prolonged strain • Real-time, high-density pH mapping demonstrated on tissue and food samples Spatial pH mapping on soft and deformable surfaces is important for applications such as wound healing assessment and food freshness mapping. However, conventional rigid pH sensors have limited use in these fields due to poor mechanical compliance, inadequate spatial resolution, and the need for wired power supplies. Here, we present an autonomous stretchable sensor array based on iridium oxide (IrO x ), powered by a low-power wireless multiplexed readout and a flexible zinc-ion battery, for 4 × 4 spatial pH sensing. These microstructurally optimised IrO x sensors exhibit a narrow super-Nernstian sensitivity of 71.25–72.69 mV/pH, with a drift below 0.01 pH/hour and robust performance after 100 stretchable cycles. The bespoke circuit employs a gain-optimised, low-noise analogue front-end with 16-channel acquisition, achieving near full-scale Analog-to-Digital Converter (ADC) utilisation (1 mV resolution) and sensitivity deviations below 1% when operated in ultra-low-power mode for wireless readout. The flexible zinc-ion battery integrates seamlessly with the circuits, providing sufficient operating time for the intended applications, and offering higher safety and biocompatibility than conventional lithium-based systems. This platform was validated on chicken and fish tissues at different stages of degradation and under mechanical strain, demonstrating strain-induced deviations below 0.02 pH. The proposed platform offers a reliable, mechanically compatible and fully integrated solution for real-time conformal biochemical mapping in clinical, environmental and food quality applications.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2026-01-29
DOI
https://doi.org/10.1016/j.snr.2026.100446
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autonomous stretchable sensor array with low-power wireless readout for spatial pH mapping

Lejun Liu, J. Huang, JINGLI LUO, Lizhou Xu et al.
Sensors and Actuators Reports
Analytical Chemistry and Sensors
article

Autonomous stretchable sensor array with low-power wireless readout for spatial pH mapping

Lejun Liu, J. Huang, JINGLI LUO, Lizhou Xu, Buddha Deka Boruah, Yingqi Kong, Yijia Zhu, B U.K. Li, Danyang Li, Yujia Li
article en

Abstract

• Stretchable 4 × 4 IrOₓ pH array with super-Nernstian (∼71 mV/pH) sensitivity • Integrated Zn-ion battery and BLE readout for autonomous wireless operation • PDMS-sealed Ag–PDMS vias enable stable pH sensing under prolonged strain • Real-time, high-density pH mapping demonstrated on tissue and food samples Spatial pH mapping on soft and deformable surfaces is important for applications such as wound healing assessment and food freshness mapping. However, conventional rigid pH sensors have limited use in these fields due to poor mechanical compliance, inadequate spatial resolution, and the need for wired power supplies. Here, we present an autonomous stretchable sensor array based on iridium oxide (IrO x ), powered by a low-power wireless multiplexed readout and a flexible zinc-ion battery, for 4 × 4 spatial pH sensing. These microstructurally optimised IrO x sensors exhibit a narrow super-Nernstian sensitivity of 71.25–72.69 mV/pH, with a drift below 0.01 pH/hour and robust performance after 100 stretchable cycles. The bespoke circuit employs a gain-optimised, low-noise analogue front-end with 16-channel acquisition, achieving near full-scale Analog-to-Digital Converter (ADC) utilisation (1 mV resolution) and sensitivity deviations below 1% when operated in ultra-low-power mode for wireless readout. The flexible zinc-ion battery integrates seamlessly with the circuits, providing sufficient operating time for the intended applications, and offering higher safety and biocompatibility than conventional lithium-based systems. This platform was validated on chicken and fish tissues at different stages of degradation and under mechanical strain, demonstrating strain-induced deviations below 0.02 pH. The proposed platform offers a reliable, mechanically compatible and fully integrated solution for real-time conformal biochemical mapping in clinical, environmental and food quality applications.

Sensors and Actuators ReportsVol. 11
Sun Yat-sen University (CN), Zhejiang University of Science and Technology (CN), University of Oxford (GB), The Seventh Affiliated Hospital of Sun Yat-sen University (CN), University College London (GB), Zhejiang University (CN), Teesside University (GB)
National Natural Science Foundation of China, Medical Research Council, Engineering and Physical Sciences Research Council
Zero hunger
Openalex Percentile: Top 75%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.