Low frequency ripple current attenuation for slow corrector power supplies in the APS Upgrade

As part of the Advanced Photon Source Upgrade (APS-U), approximately one thousand bipolar power supplies were installed to power the slow corrector magnets. During the APS-U commissioning, a 1Hz harmonic was detected in the beam motion. This harmonic originates from the 480V AC grid, caused by the booster ramping power supply operating at 1 Hz. The resulting grid disturbance introduced low-frequency ripples into both the corrector magnet power supplies and the L-Bend M1/M2 supplies, leading to the observed 1 Hz beam motion. This paper proposes two methods to mitigate these ripples in the corrector supplies: setpoint compensation using repetitive control, and regulation circuit adjustments through a simple jumper reconfiguration. The second approach was adopted and applied to all slow corrector magnet power supplies. Operational data showed that the low-frequency ripples were significantly attenuated in the corrector supplies, and in combination with fine-tuning of the L-Bend M1/M2 supplies, the 1 Hz beam motion was successfully eliminated.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-wep057
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low frequency ripple current attenuation for slow corrector power supplies in the APS Upgrade

Yang Ruan, Fernando Rafael
JACOW
Particle Accelerators and Free-Electron Lasers
article

Low frequency ripple current attenuation for slow corrector power supplies in the APS Upgrade

Yang Ruan, Fernando Rafael
article en

Abstract

As part of the Advanced Photon Source Upgrade (APS-U), approximately one thousand bipolar power supplies were installed to power the slow corrector magnets. During the APS-U commissioning, a 1Hz harmonic was detected in the beam motion. This harmonic originates from the 480V AC grid, caused by the booster ramping power supply operating at 1 Hz. The resulting grid disturbance introduced low-frequency ripples into both the corrector magnet power supplies and the L-Bend M1/M2 supplies, leading to the observed 1 Hz beam motion. This paper proposes two methods to mitigate these ripples in the corrector supplies: setpoint compensation using repetitive control, and regulation circuit adjustments through a simple jumper reconfiguration. The second approach was adopted and applied to all slow corrector magnet power supplies. Operational data showed that the low-frequency ripples were significantly attenuated in the corrector supplies, and in combination with fine-tuning of the L-Bend M1/M2 supplies, the 1 Hz beam motion was successfully eliminated.

JACOW
Affordable and clean energy
Openalex Percentile: Top 73%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.