Digital camera performance in a high-radiation accelerator test beam facility

Digital cameras are critical diagnostics at test beam facilities. At FACET-II, there are over 100 digital cameras in operation. The 10 GeV electron beams cause high levels of radiation, which makes profile monitors susceptible to two types of failures: single-event upsets (SEU) and permanent death. The Camera Watchdog software was deployed to monitor and automatically power cycle cameras in the case of an SEU. The Camera Watchdog also updates the total number of reboots executed for each camera. Additionally, digital radiation monitors (RADFETs) have been installed at the locations of 10 cameras. We report on the findings from the study and discuss how they can be used to mitigate radiation damage to digital cameras.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-mop032
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital camera performance in a high-radiation accelerator test beam facility

S. M. Perez, Spencer Gessner, Carsten Hast, Ivan Rajkovic
JACOW
Radiation Effects in Electronics
article

Digital camera performance in a high-radiation accelerator test beam facility

S. M. Perez, Spencer Gessner, Carsten Hast, Ivan Rajkovic
article en

Abstract

Digital cameras are critical diagnostics at test beam facilities. At FACET-II, there are over 100 digital cameras in operation. The 10 GeV electron beams cause high levels of radiation, which makes profile monitors susceptible to two types of failures: single-event upsets (SEU) and permanent death. The Camera Watchdog software was deployed to monitor and automatically power cycle cameras in the case of an SEU. The Camera Watchdog also updates the total number of reboots executed for each camera. Additionally, digital radiation monitors (RADFETs) have been installed at the locations of 10 cameras. We report on the findings from the study and discuss how they can be used to mitigate radiation damage to digital cameras.

JACOW
Good health and well-being
Openalex Percentile: Top 73%
Radiation Effects in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.