Reducing environmental footprint in power systems through high‐performance epoxy–nanocarbon insulation

Abstract Transformers are among the most crucial components of electric distribution and transmission systems, and the grid's stability and dependability are directly impacted by their operation. Polymeric insulation used in transformers and electrical allied areas has recently created an enormous revolution. An epoxy polymer matrix with carbon‐based nano reinforcement is subjected to analyze the possibilities of incorporation as an insulant in dry type transformer. The fabrication process was optimized by varying hardener content and stirring speed using a central composite design integrated with response surface methodology. The developed epoxy/carbon nanocomposites were evaluated for dielectric strength, thermal conductivity, tensile strength, Izod impact resistance, and morphological characteristics to determine their suitability as solid insulation for dry‐type transformer applications. Some algorithm combinations [random forest, neural network, gradient boosting, XGboost gain, and response surface methodology] are examined to determine the most optimal. This study revealed that 6.5% of the sample performed well for all the properties of the study. The optimized sample had a dielectric strength of 140 V/mm, a thermal conductivity of 0.45 W/m K, and an Izod impact of 0.26 (J/mm). RSM was ultimately determined to be a more accurate prediction model than the other algorithms based on the obtained model results. The results indicate that, with an accuracy of 94% for dielectric strength, 98% for tensile strength, 98.4% for Izod impact, and 96% for thermal conductivity, the RSM performs best in forecasting the revolutionizing of the transformer's insulation.

Authors

Institutions

Publication Details

Journal
Environmental Progress & Sustainable Energy
Published
2026-01-28
DOI
https://doi.org/10.1002/ep.70357
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing environmental footprint in power systems through high‐performance epoxy–nanocarbon insulation

Gurukarthik Babu Balachandran, Hariharasudhan Thangaraj, Muthu Eshwaran Ramachandran, Manikandan Pandian
Environmental Progress & Sustainable Energy
High voltage insulation and dielectric phenomena
article

Reducing environmental footprint in power systems through high‐performance epoxy–nanocarbon insulation

Gurukarthik Babu Balachandran, Hariharasudhan Thangaraj, Muthu Eshwaran Ramachandran, Manikandan Pandian
article en

Abstract

Abstract Transformers are among the most crucial components of electric distribution and transmission systems, and the grid's stability and dependability are directly impacted by their operation. Polymeric insulation used in transformers and electrical allied areas has recently created an enormous revolution. An epoxy polymer matrix with carbon‐based nano reinforcement is subjected to analyze the possibilities of incorporation as an insulant in dry type transformer. The fabrication process was optimized by varying hardener content and stirring speed using a central composite design integrated with response surface methodology. The developed epoxy/carbon nanocomposites were evaluated for dielectric strength, thermal conductivity, tensile strength, Izod impact resistance, and morphological characteristics to determine their suitability as solid insulation for dry‐type transformer applications. Some algorithm combinations [random forest, neural network, gradient boosting, XGboost gain, and response surface methodology] are examined to determine the most optimal. This study revealed that 6.5% of the sample performed well for all the properties of the study. The optimized sample had a dielectric strength of 140 V/mm, a thermal conductivity of 0.45 W/m K, and an Izod impact of 0.26 (J/mm). RSM was ultimately determined to be a more accurate prediction model than the other algorithms based on the obtained model results. The results indicate that, with an accuracy of 94% for dielectric strength, 98% for tensile strength, 98.4% for Izod impact, and 96% for thermal conductivity, the RSM performs best in forecasting the revolutionizing of the transformer's insulation.

Environmental Progress & Sustainable Energy
ASA College (US), Centre for Artificial Intelligence and Robotics (IN), SRM University (IN)
Life in Land
Openalex Percentile: Top 74%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.