Improved Load Frequency Control Design for Interconnected Power Systems

Managing frequency stability in modern interconnected power systems is a critical challenge, particularly under continuous load variations and increasing system complexity. In response to these challenges, this study introduces an Improved Grey Wolf Optimizer (IGWO)-based Proportional–Integral–Derivative (PID) controller as a solution for effective Load Frequency Control (LFC). The proposed method is tested on interconnected power systems integrating thermal (reheat and non-reheat) and hydropower plants. The simulations focus on continuous load variation and nonlinearity cases, where the GRC block is added in the model to closely mimic real-world operating conditions. The findings demonstrate that the IGWO-PID controller outperforms by achieving faster stabilization, minimizing frequency deviations, and ensuring robust performance compared to the Particle Swarm Optimization (PSO) algorithm. These results highlight the controller’s adaptability and scalability, offering a reliable approach to maintaining stability and operational efficiency in interconnected power systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-01-29
DOI
https://doi.org/10.3390/en19030702
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Load Frequency Control Design for Interconnected Power Systems

D. Tan, Thanh The Van, Van Van Huynh, Hoai Duong Minh
Energies
Frequency Control in Power Systems
article

Improved Load Frequency Control Design for Interconnected Power Systems

D. Tan, Thanh The Van, Van Van Huynh, Hoai Duong Minh
article en

Abstract

Managing frequency stability in modern interconnected power systems is a critical challenge, particularly under continuous load variations and increasing system complexity. In response to these challenges, this study introduces an Improved Grey Wolf Optimizer (IGWO)-based Proportional–Integral–Derivative (PID) controller as a solution for effective Load Frequency Control (LFC). The proposed method is tested on interconnected power systems integrating thermal (reheat and non-reheat) and hydropower plants. The simulations focus on continuous load variation and nonlinearity cases, where the GRC block is added in the model to closely mimic real-world operating conditions. The findings demonstrate that the IGWO-PID controller outperforms by achieving faster stabilization, minimizing frequency deviations, and ensuring robust performance compared to the Particle Swarm Optimization (PSO) algorithm. These results highlight the controller’s adaptability and scalability, offering a reliable approach to maintaining stability and operational efficiency in interconnected power systems.

EnergiesVol. 19(3)
Ton Duc Thang University (VN)
Affordable and clean energy
Openalex Percentile: Top 73%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.