Optimal Electrical Dispatch by Time Blocks in Systems with Conventional Generation, Renewable, and Storage Systems Using DC Flows

Sustained demand growth and the increasing share of renewable energy sources pose challenges for the operation of modern electrical systems. The variability in wind and solar photovoltaic generation causes temporary imbalances between supply and demand, requiring the incorporation of energy management and storage strategies to guarantee supply. In this context, the need arises to develop optimization models that allow for efficient energy dispatch, minimizing costs and promoting the appropriate use of both conventional and renewable resources. This study formulated a time block dispatch optimization model implemented in the IEEE 24-node system, integrating thermal, hydroelectric, photovoltaic, wind, and energy storage systems. The methodology was based on DC power flows and was developed in MATLAB R2024b, incorporating nodal balance constraints, transmission and generation capacity limits, as well as the operating conditions of the storage systems. The model allowed for the evaluation of both energy and economic performance, validating its behavior under conditions of peak demand and renewable variability. The results demonstrate that the inclusion of energy storage systems allows for a reduction in high-cost thermal generation, optimizing demand coverage with a greater share of renewable energy. An average storage efficiency of 85.5% was achieved, and total system costs were reduced by USD 40,392.39 per day, equivalent to annual savings of USD 14.75 million. Furthermore, power flows remained below 85% of transmission capacity, confirming the proper operation of the grid. In this sense, the model fulfills the proposed objectives and proves to be a tool for energy planning and the technical-economic integration of storage in electrical networks.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-01-29
DOI
https://doi.org/10.3390/app16031372
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Electrical Dispatch by Time Blocks in Systems with Conventional Generation, Renewable, and Storage Systems Using DC Flows

Erika Alejandra Paredes Paredes, Juan Lata‐García, Edwin Chilig
Applied Sciences
Integrated Energy Systems Optimization
article

Optimal Electrical Dispatch by Time Blocks in Systems with Conventional Generation, Renewable, and Storage Systems Using DC Flows

Erika Alejandra Paredes Paredes, Juan Lata‐García, Edwin Chilig
article en

Abstract

Sustained demand growth and the increasing share of renewable energy sources pose challenges for the operation of modern electrical systems. The variability in wind and solar photovoltaic generation causes temporary imbalances between supply and demand, requiring the incorporation of energy management and storage strategies to guarantee supply. In this context, the need arises to develop optimization models that allow for efficient energy dispatch, minimizing costs and promoting the appropriate use of both conventional and renewable resources. This study formulated a time block dispatch optimization model implemented in the IEEE 24-node system, integrating thermal, hydroelectric, photovoltaic, wind, and energy storage systems. The methodology was based on DC power flows and was developed in MATLAB R2024b, incorporating nodal balance constraints, transmission and generation capacity limits, as well as the operating conditions of the storage systems. The model allowed for the evaluation of both energy and economic performance, validating its behavior under conditions of peak demand and renewable variability. The results demonstrate that the inclusion of energy storage systems allows for a reduction in high-cost thermal generation, optimizing demand coverage with a greater share of renewable energy. An average storage efficiency of 85.5% was achieved, and total system costs were reduced by USD 40,392.39 per day, equivalent to annual savings of USD 14.75 million. Furthermore, power flows remained below 85% of transmission capacity, confirming the proper operation of the grid. In this sense, the model fulfills the proposed objectives and proves to be a tool for energy planning and the technical-economic integration of storage in electrical networks.

Applied SciencesVol. 16(3)
Politecnica Salesiana University (EC)
Universidad Politécnica Salesiana del Ecuador
Affordable and clean energy
Openalex Percentile: Top 73%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.