Heavy ion implantation analysis in graphite for the FRIB charge selector

An advanced charge selector is currently under development at the Facility for Rare Isotope Beams (FRIB) to intercept unwanted charge states of stripped heavy ion beams. Rotating graphite wheels are employed to absorb beams with a power up to 5 kW and a size as small as an rms width of 0.7 mm × 1.25 mm. The implantation of beam ions and accumulated radiation damage affect the material properties, potentially leading to its structural failure. Determining the foreign ion accumulation behavior is one critical aspect for predicting the operational lifetime of the graphite wheels. In this study, ion implantation distribution was first characterized using SRIM simulations, then coupled with Monte Carlo analysis to account for wheel geometry and rotational dynamics. The evolution of the ion concentration profiles was subsequently determined considering the diffusion effects. The analysis reveals that strategic beam positioning optimization, combined with diffusion effects, substantially reduces peak ion concentrations and implantation rates, providing essential data for graphite wheel lifetime assessment.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-wep042
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heavy ion implantation analysis in graphite for the FRIB charge selector

Alexander Plastun, Xiuli Wang, Takuji Kanemura
JACOW
Graphite, nuclear technology, radiation studies
article

Heavy ion implantation analysis in graphite for the FRIB charge selector

Alexander Plastun, Xiuli Wang, Takuji Kanemura
article en

Abstract

An advanced charge selector is currently under development at the Facility for Rare Isotope Beams (FRIB) to intercept unwanted charge states of stripped heavy ion beams. Rotating graphite wheels are employed to absorb beams with a power up to 5 kW and a size as small as an rms width of 0.7 mm × 1.25 mm. The implantation of beam ions and accumulated radiation damage affect the material properties, potentially leading to its structural failure. Determining the foreign ion accumulation behavior is one critical aspect for predicting the operational lifetime of the graphite wheels. In this study, ion implantation distribution was first characterized using SRIM simulations, then coupled with Monte Carlo analysis to account for wheel geometry and rotational dynamics. The evolution of the ion concentration profiles was subsequently determined considering the diffusion effects. The analysis reveals that strategic beam positioning optimization, combined with diffusion effects, substantially reduces peak ion concentrations and implantation rates, providing essential data for graphite wheel lifetime assessment.

JACOW
Openalex Percentile: Top 74%
Graphite, nuclear technology, radiation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.