Optimizing Effective Labeling Efficiency in MINFLUX 3D DNA-PAINT Microscopy by Maximizing Marker Detection Probability.

MINFLUX is a powerful single-molecule approach capable of achieving high spatially isotropic resolution in three dimensions. Current implementations collect localizations strictly serially, but criteria for when to terminate acquisition are often unclear. We therefore systematically investigate the time course of effective labeling efficiency (ELE) and achievable saturation values in MINFLUX 3D DNA-PAINT microscopy of Nup96 proteins in a U-2 OS-Nup96-mEGFP modified cell line using a commercial MINFLUX microscope. ELE was measured using a quantitative procedure based on maximum-likelihood template fitting. We collected data measured over various scan sizes and achieved ELE values of ∼60% after passing a time interval dependent on the region size, typically requiring long-duration acquisitions over several hours. Our data and a simple model suggest that maximizing marker detection is key to achieving the limits set by chemical labeling efficiency. A factor limiting the marker detection probability when using conventional DNA-PAINT markers is docking strand site-loss, observed over the duration required to build up the image data of MINFLUX acquisitions, which also limits the achievable number of labeling site visits to values around 1-3. Using repeat DNA-PAINT, i.e., employing oligonucleotide sequences with repeated docking sites, we observed greatly reduced site-loss and could increase the number of individual visits to site locations by more than 3-fold over the same period. Additionally, this enabled increasing stringency criteria for labeling (i.e., higher threshold values) and maximizing marker detection probabilities so that ELE reaches the limits set by chemical labeling efficiency.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-07
DOI
https://doi.org/10.48620/94172
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Effective Labeling Efficiency in MINFLUX 3D DNA-PAINT Microscopy by Maximizing Marker Detection Probability.

Christian Soeller, Alexander H. Clowsley, Javier Casares-Arias, Alexandre F. E. Bokhobza
Open Access CRIS of the University of Bern
Advanced Fluorescence Microscopy Techniques
article

Optimizing Effective Labeling Efficiency in MINFLUX 3D DNA-PAINT Microscopy by Maximizing Marker Detection Probability.

Christian Soeller, Alexander H. Clowsley, Javier Casares-Arias, Alexandre F. E. Bokhobza
article en

Abstract

MINFLUX is a powerful single-molecule approach capable of achieving high spatially isotropic resolution in three dimensions. Current implementations collect localizations strictly serially, but criteria for when to terminate acquisition are often unclear. We therefore systematically investigate the time course of effective labeling efficiency (ELE) and achievable saturation values in MINFLUX 3D DNA-PAINT microscopy of Nup96 proteins in a U-2 OS-Nup96-mEGFP modified cell line using a commercial MINFLUX microscope. ELE was measured using a quantitative procedure based on maximum-likelihood template fitting. We collected data measured over various scan sizes and achieved ELE values of ∼60% after passing a time interval dependent on the region size, typically requiring long-duration acquisitions over several hours. Our data and a simple model suggest that maximizing marker detection is key to achieving the limits set by chemical labeling efficiency. A factor limiting the marker detection probability when using conventional DNA-PAINT markers is docking strand site-loss, observed over the duration required to build up the image data of MINFLUX acquisitions, which also limits the achievable number of labeling site visits to values around 1-3. Using repeat DNA-PAINT, i.e., employing oligonucleotide sequences with repeated docking sites, we observed greatly reduced site-loss and could increase the number of individual visits to site locations by more than 3-fold over the same period. Additionally, this enabled increasing stringency criteria for labeling (i.e., higher threshold values) and maximizing marker detection probabilities so that ELE reaches the limits set by chemical labeling efficiency.

Open Access CRIS of the University of Bern
Leibniz University Hannover (DE), Czech Academy of Sciences, Institute of Physiology (CZ)
Openalex Percentile: Top 76%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.