Biocompatible and Flexible Cellulose Film for the Reversible Colourimetric Monitoring of pH and Mg (II)

Novel colourimetric sensors are readily devised by combining multifunctional (nano)materials with miniature optoelectronic components. The demand to detect and monitor metal ions has resulted in the invention of new colourimetric sensing schemes, especially for use at the Point-of-Need (PoN). Nonetheless, the design of fully reversible optical materials for continuous real-time ion monitoring remains a bottleneck in the practical realisation of sensors. Magnesium ion is vital to physiological and environmental processes, but monitoring can be challenging, particularly in the presence of Ca<sup>2+</sup> as a cross-sensitive interferent in real samples. In this work, a chromophore molecule Hyphan I (1-(2-hydroxy-5-ß-hydroxyethylsulfonyl-phenyl-azo)-2-naphthol) has been grafted onto a cellulose matrix with a simple one-pot vinylsulfonyl process, to form a transparent, biocompatible and highly flexible thin-film colourimetric magnesium ion sensing material (Cellulose Film with Hyphan-CFH). The CFH film has a pH response time of <60 s over the pH range 4 to 9, with a p<i>K</i><sub>a1</sub> = 5.8. The LOD and LOQ for Mg<sup>2+</sup> at pH 8 are 0.089 mM and 0.318 mM, respectively, with an RSD = 0.93%. The CFH film exhibits negligible interference from alkaline and alkaline earth metals, but irreversibly binds certain transition metals (Fe<sup>3+</sup>, Cu<sup>2+</sup> and Zn<sup>2+</sup>). The CFH material has a fast and fully reversible colourimetric response to pH and Mg<sup>2+</sup> over physiologically relevant ranges without interference by Ca<sup>2+</sup>, demonstrating good potential for integration into microfluidic systems and wearable sensors for biofluid monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-29
DOI
https://doi.org/10.3390/s26030880
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biocompatible and Flexible Cellulose Film for the Reversible Colourimetric Monitoring of pH and Mg (II)

Deepak Joshy, Matthew D. Steinberg, Gerhard J. Mohr, Cindy Schaude et al.
Sensors
Analytical Chemistry and Sensors
article

Biocompatible and Flexible Cellulose Film for the Reversible Colourimetric Monitoring of pH and Mg (II)

Deepak Joshy, Matthew D. Steinberg, Gerhard J. Mohr, Cindy Schaude, Ivana Murković Steinberg, Iva Karneluti
article en

Abstract

Novel colourimetric sensors are readily devised by combining multifunctional (nano)materials with miniature optoelectronic components. The demand to detect and monitor metal ions has resulted in the invention of new colourimetric sensing schemes, especially for use at the Point-of-Need (PoN). Nonetheless, the design of fully reversible optical materials for continuous real-time ion monitoring remains a bottleneck in the practical realisation of sensors. Magnesium ion is vital to physiological and environmental processes, but monitoring can be challenging, particularly in the presence of Ca<sup>2+</sup> as a cross-sensitive interferent in real samples. In this work, a chromophore molecule Hyphan I (1-(2-hydroxy-5-ß-hydroxyethylsulfonyl-phenyl-azo)-2-naphthol) has been grafted onto a cellulose matrix with a simple one-pot vinylsulfonyl process, to form a transparent, biocompatible and highly flexible thin-film colourimetric magnesium ion sensing material (Cellulose Film with Hyphan-CFH). The CFH film has a pH response time of <60 s over the pH range 4 to 9, with a p<i>K</i><sub>a1</sub> = 5.8. The LOD and LOQ for Mg<sup>2+</sup> at pH 8 are 0.089 mM and 0.318 mM, respectively, with an RSD = 0.93%. The CFH film exhibits negligible interference from alkaline and alkaline earth metals, but irreversibly binds certain transition metals (Fe<sup>3+</sup>, Cu<sup>2+</sup> and Zn<sup>2+</sup>). The CFH material has a fast and fully reversible colourimetric response to pH and Mg<sup>2+</sup> over physiologically relevant ranges without interference by Ca<sup>2+</sup>, demonstrating good potential for integration into microfluidic systems and wearable sensors for biofluid monitoring.

SensorsVol. 26(3)
Joanneum Research (AT), University of Zagreb (HR), WFS Technologies (United Kingdom) (GB)
European Commission, Hrvatska Zaklada za Znanost, Österreichische Forschungsförderungsgesellschaft
Life in Land
Openalex Percentile: Top 76%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.