Sub-10 Nanomole Perchlorate δ <sup>37</sup> Cl, δ <sup>18</sup> O, and Δ <sup>17</sup> O Measurements by ESI-Orbitrap-MS

Perchlorate (ClO<sub>4</sub><sup>-</sup>) is found in both Earth and Martian surface environments, yet its formation mechanism remains enigmatic. ClO<sub>4</sub><sup>-</sup> isotope composition can help to identify the formation mechanism/source, but the conventional gas-source isotope ratio mass spectrometry (IRMS) method requires micromole or larger sample sizes together with tedious mineral precipitation steps. Here, a capable method for measuring δ<sup>37</sup>Cl, δ<sup>18</sup>O, and Δ<sup>17</sup>O values of trace ClO<sub>4</sub><sup>-</sup> (<10 nmol) was established using the electrospray ionization Orbitrap MS (ESI-Orbitrap-MS) equipped with a dual-inlet system. After testing shot noise limit, acquisition error, and Allan variance, we have identified an optimal analysis duration of 11 min with 7 cycles of sample-reference measurement. A three-point calibration against USGS standards demonstrated that higher automatic gain control (AGC) targets (over 1 × 10<sup>6</sup>) can improve Δ<sup>17</sup>O precision, but inducing scale distortion caused by space-charge effects for the δ<sup>18</sup>O and Δ<sup>17</sup>O. Our method could reach the accuracy of 0.6‰ for Δ<sup>17</sup>O (AGC Target ≈ 2 × 10<sup>6</sup>) and 0.6‰ and 0.7‰ for δ<sup>37</sup>Cl and δ<sup>18</sup>O (AGC Target ≈ 1 × 10<sup>6</sup>), respectively, in 8.40 nmol sample. Across a sample size range of 0.84 to 8.40 nmol of ClO<sub>4</sub><sup>-</sup>, the uncertainties remained ≤1.4‰ under both optimal and nonoptimal electrospray conditions. Man-made ClO<sub>4</sub><sup>-</sup> from commercial sources and natural ClO<sub>4</sub><sup>-</sup> from the Atacama Desert exhibited IRMS differences within 1‰ after purification and concentration control by ion chromatography. The method enables perchlorate isotope application to atmospheric, environmental, and planetary samples previously inaccessible due to sample scarcity.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-29
DOI
https://doi.org/10.1021/acs.analchem.5c06548
Primary Topic
Chemical Analysis and Environmental Impact
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sub-10 Nanomole Perchlorate δ 37 Cl, δ 18 O, and Δ 17 O Measurements by ESI-Orbitrap-MS

Zhao Wei, Shohei Hattori, Yu Hong, Bao Huiming et al.
Analytical Chemistry
Chemical Analysis and Environmental Impact
article

Sub-10 Nanomole Perchlorate δ 37 Cl, δ 18 O, and Δ 17 O Measurements by ESI-Orbitrap-MS

Zhao Wei, Shohei Hattori, Yu Hong, Bao Huiming, Longchen Zhu, Yongbo Peng, Nils Johannes Kuhlbusch, Zhenfei Wang
article en

Abstract

Perchlorate (ClO<sub>4</sub><sup>-</sup>) is found in both Earth and Martian surface environments, yet its formation mechanism remains enigmatic. ClO<sub>4</sub><sup>-</sup> isotope composition can help to identify the formation mechanism/source, but the conventional gas-source isotope ratio mass spectrometry (IRMS) method requires micromole or larger sample sizes together with tedious mineral precipitation steps. Here, a capable method for measuring δ<sup>37</sup>Cl, δ<sup>18</sup>O, and Δ<sup>17</sup>O values of trace ClO<sub>4</sub><sup>-</sup> (<10 nmol) was established using the electrospray ionization Orbitrap MS (ESI-Orbitrap-MS) equipped with a dual-inlet system. After testing shot noise limit, acquisition error, and Allan variance, we have identified an optimal analysis duration of 11 min with 7 cycles of sample-reference measurement. A three-point calibration against USGS standards demonstrated that higher automatic gain control (AGC) targets (over 1 × 10<sup>6</sup>) can improve Δ<sup>17</sup>O precision, but inducing scale distortion caused by space-charge effects for the δ<sup>18</sup>O and Δ<sup>17</sup>O. Our method could reach the accuracy of 0.6‰ for Δ<sup>17</sup>O (AGC Target ≈ 2 × 10<sup>6</sup>) and 0.6‰ and 0.7‰ for δ<sup>37</sup>Cl and δ<sup>18</sup>O (AGC Target ≈ 1 × 10<sup>6</sup>), respectively, in 8.40 nmol sample. Across a sample size range of 0.84 to 8.40 nmol of ClO<sub>4</sub><sup>-</sup>, the uncertainties remained ≤1.4‰ under both optimal and nonoptimal electrospray conditions. Man-made ClO<sub>4</sub><sup>-</sup> from commercial sources and natural ClO<sub>4</sub><sup>-</sup> from the Atacama Desert exhibited IRMS differences within 1‰ after purification and concentration control by ion chromatography. The method enables perchlorate isotope application to atmospheric, environmental, and planetary samples previously inaccessible due to sample scarcity.

Analytical ChemistryVol. 98(8)
University of Münster (DE), Thermo Fisher Scientific (Canada) (CA), Nanjing University (CN)
Openalex Percentile: Top 75%
Chemical Analysis and Environmental Impact
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.