Chemosensing of an Autism Biomarker, Gamma-Aminobutyric Acid, by Electropolymerized Molecularly Imprinted Polymers

We electrochemically synthesized molecularly imprinted polymer (MIP) films and simultaneously deposited them onto an interdigitated electrode array (IDEA) and a classical Pt disk electrode to devise chemosensors for the selective determination of gamma-aminobutyric acid (GABA), a biomarker of autism spectrum disorder. <i>p</i>-<i>Bis</i>(2,2'-bithien-5-yl)methyl phenol 2-hydroxy acetamide ether was used as the functional monomer due to its ability to form a stable prepolymerization complex with the GABA template in solution. The highest stability of the prepolymerization complex of GABA with different functional monomers directed the choice of the above functional monomer. The structures of these complexes were optimized using DFT calculations. Potentiodynamic electropolymerization was performed to deposit prepolymerization template and functional monomer complexes on different electrodes. After removing template molecules to generate selective molecular cavities in the resulting MIPs, we evaluated the analytical performance of these MIP films when integrated into electrochemical sensing platforms. We integrated differential pulse voltammetry (DPV) or electrochemical impedance spectroscopy (EIS) transductions with the MIP film-coated electrodes and identified EIS as the most effective for point-of-care GABA determinations. Using EIS, an MIP-film-coated platinum disk electrode detected GABA in a linear dynamic concentration range of 0.19-1.6 μM, with a limit of detection (LOD) of 0.13 μM. The MIP film deposited on the IDEA enabled GABA determination with EIS over a broader range of 8-240 μM, with an LOD of 0.39 μM, highlighting its potential for clinical applications. The EIS-determined imprinting factor was 2.7. The chemosensors were selective with respect to structural analogues of GABA. Finally, we successfully measured GABA concentrations in human serum samples, confirming the clinical applicability of the developed GABA determination method.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-01-29
DOI
https://doi.org/10.1021/acssensors.5c02424
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chemosensing of an Autism Biomarker, Gamma-Aminobutyric Acid, by Electropolymerized Molecularly Imprinted Polymers

Nabila Yasmeen, Wojciech Lisowski, Włodzimierz Kutner, Krzysztof Noworyta et al.
ACS Sensors
Analytical chemistry methods development
article

Chemosensing of an Autism Biomarker, Gamma-Aminobutyric Acid, by Electropolymerized Molecularly Imprinted Polymers

Nabila Yasmeen, Wojciech Lisowski, Włodzimierz Kutner, Krzysztof Noworyta, Francis Wallace D'Souza, Joanna Piechowska, Piyush Sindhu Sharma
article en

Abstract

We electrochemically synthesized molecularly imprinted polymer (MIP) films and simultaneously deposited them onto an interdigitated electrode array (IDEA) and a classical Pt disk electrode to devise chemosensors for the selective determination of gamma-aminobutyric acid (GABA), a biomarker of autism spectrum disorder. <i>p</i>-<i>Bis</i>(2,2'-bithien-5-yl)methyl phenol 2-hydroxy acetamide ether was used as the functional monomer due to its ability to form a stable prepolymerization complex with the GABA template in solution. The highest stability of the prepolymerization complex of GABA with different functional monomers directed the choice of the above functional monomer. The structures of these complexes were optimized using DFT calculations. Potentiodynamic electropolymerization was performed to deposit prepolymerization template and functional monomer complexes on different electrodes. After removing template molecules to generate selective molecular cavities in the resulting MIPs, we evaluated the analytical performance of these MIP films when integrated into electrochemical sensing platforms. We integrated differential pulse voltammetry (DPV) or electrochemical impedance spectroscopy (EIS) transductions with the MIP film-coated electrodes and identified EIS as the most effective for point-of-care GABA determinations. Using EIS, an MIP-film-coated platinum disk electrode detected GABA in a linear dynamic concentration range of 0.19-1.6 μM, with a limit of detection (LOD) of 0.13 μM. The MIP film deposited on the IDEA enabled GABA determination with EIS over a broader range of 8-240 μM, with an LOD of 0.39 μM, highlighting its potential for clinical applications. The EIS-determined imprinting factor was 2.7. The chemosensors were selective with respect to structural analogues of GABA. Finally, we successfully measured GABA concentrations in human serum samples, confirming the clinical applicability of the developed GABA determination method.

ACS SensorsVol. 11(2)
University of North Texas (US), Institute of Physical Chemistry (PL), Cardinal Stefan Wyszynski University in Warsaw (PL), Polish Academy of Sciences (PL)
Openalex Percentile: Top 72%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.