A microfluidic platform for the co-culturing of microtissues with continuously recirculating suspension cells

In vitro evaluation of novel therapeutic approaches often fails to reliably predict efficacy and toxicity, especially when recapitulating conditions involving recirculating cells. Current testing strategies are often based on static co-culturing of cells in suspension and 3D tissue models, where cell sedimentation on the target tissue can occur. The observed effects may then mostly be a consequence of sedimentation and of the corresponding forced cell-tissue interactions. The realization of continuous medium flow helps to better recapitulate physiological conditions and cell-tissue interactions. To tackle current limitations of perfused organ-on-chip approaches, we developed a microfluidic chip and operation concept, which prevents undesired sedimentation and accumulation of suspended cells during multiple days by relying on gravity-driven perfusion. Our platform, which we termed "human immune flow (hiFlow) chip", enables to co-culture cells in suspension with up to 7 preformed microtissue models. Here, we present the design principle and operation of the platform, and we validate its performance by culturing cells and microtissues of a variety of different origins. Cells and tissues could be monitored on chip via high-resolution microscopy, while cell suspensions and microtissues could be easily retrieved for off-chip analysis. Our results demonstrate that primary immune cells and a range of different spheroid models of healthy and diseased tissues can be maintained for over 6 days on chip. As proof-of-concept cell-tissue interaction assay, we used an antibody treatment against diffuse midline glioma, a highly aggressive pediatric tumor. We are confident that our platform will help to increase the prediction power of in vitro preclinical testing of novel therapeutics that rely on the interaction of circulating cells with organ tissues.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-10-11
DOI
https://doi.org/10.5167/uzh-283499
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A microfluidic platform for the co-culturing of microtissues with continuously recirculating suspension cells

Andreas Hierlemann, Bettina Kritzer, Sandra Laternser, Christian Lohasz et al.
Universität Zürich, ZORA
3D Printing in Biomedical Research
article

A microfluidic platform for the co-culturing of microtissues with continuously recirculating suspension cells

Andreas Hierlemann, Bettina Kritzer, Sandra Laternser, Christian Lohasz, Mario M. Modena, Avni Mehta, Laure‐Anne Ligeon, Olivier Frey, Dzhansu Hasanova, Svenja Lützow, Michal Rudnik, Javad Nazarian, Lisa Hölting, Tamara Häfeli
article en

Abstract

In vitro evaluation of novel therapeutic approaches often fails to reliably predict efficacy and toxicity, especially when recapitulating conditions involving recirculating cells. Current testing strategies are often based on static co-culturing of cells in suspension and 3D tissue models, where cell sedimentation on the target tissue can occur. The observed effects may then mostly be a consequence of sedimentation and of the corresponding forced cell-tissue interactions. The realization of continuous medium flow helps to better recapitulate physiological conditions and cell-tissue interactions. To tackle current limitations of perfused organ-on-chip approaches, we developed a microfluidic chip and operation concept, which prevents undesired sedimentation and accumulation of suspended cells during multiple days by relying on gravity-driven perfusion. Our platform, which we termed "human immune flow (hiFlow) chip", enables to co-culture cells in suspension with up to 7 preformed microtissue models. Here, we present the design principle and operation of the platform, and we validate its performance by culturing cells and microtissues of a variety of different origins. Cells and tissues could be monitored on chip via high-resolution microscopy, while cell suspensions and microtissues could be easily retrieved for off-chip analysis. Our results demonstrate that primary immune cells and a range of different spheroid models of healthy and diseased tissues can be maintained for over 6 days on chip. As proof-of-concept cell-tissue interaction assay, we used an antibody treatment against diffuse midline glioma, a highly aggressive pediatric tumor. We are confident that our platform will help to increase the prediction power of in vitro preclinical testing of novel therapeutics that rely on the interaction of circulating cells with organ tissues.

Universität Zürich, ZORA
Openalex Percentile: Top 39%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.