Implementation of electron–X-ray beam overlap diagnostic instrument at LCLS

We report on the commissioning results of the newly implemented Beam Overlap Diagnostic (BOD) instrument, known as Station F, at the hard X-ray line of the Linac Coherent Light Source (LCLS). As part of the CBXFEL project at SLAC, Station F is designed to facilitate alignment between the relativistic electron beam entering the undulator hall and the X-rays returning from the CBXFEL cavity via the return line. The station features two interchangeable targets: (1) a diamond screen for direct imaging of the LCLS electron beam, enabling measurement of its transverse size and position; and (2) a YAP:Ce scintillator for detecting faint returning X-rays when the diamond’s sensitivity is insufficient. Emission from either target, whether generated by electron-induced cathodoluminescence or X-ray-induced scintillation, is captured using a fast-gated optical/UV camera. We present results from recent commissioning runs, including direct electron beam imaging, beam size and position characterization in both single- and two-bunch modes, and observations of coherent radiation linked to early microbunching, with implications for the laser heater configuration.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-thp045
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of electron–X-ray beam overlap diagnostic instrument at LCLS

G. Lanza, Mario Balcazar, Hengzi Wang, Maria Alessandra Montironi et al.
JACOW
Particle Accelerators and Free-Electron Lasers
article

Implementation of electron–X-ray beam overlap diagnostic instrument at LCLS

G. Lanza, Mario Balcazar, Hengzi Wang, Maria Alessandra Montironi, Xavi Permanyer, Alberto Lutman, Franz-Josef Decker, Courtney Curtis, Zhirong Huang, Aliaksei Halavanau, Diling Zhu
article en

Abstract

We report on the commissioning results of the newly implemented Beam Overlap Diagnostic (BOD) instrument, known as Station F, at the hard X-ray line of the Linac Coherent Light Source (LCLS). As part of the CBXFEL project at SLAC, Station F is designed to facilitate alignment between the relativistic electron beam entering the undulator hall and the X-rays returning from the CBXFEL cavity via the return line. The station features two interchangeable targets: (1) a diamond screen for direct imaging of the LCLS electron beam, enabling measurement of its transverse size and position; and (2) a YAP:Ce scintillator for detecting faint returning X-rays when the diamond’s sensitivity is insufficient. Emission from either target, whether generated by electron-induced cathodoluminescence or X-ray-induced scintillation, is captured using a fast-gated optical/UV camera. We present results from recent commissioning runs, including direct electron beam imaging, beam size and position characterization in both single- and two-bunch modes, and observations of coherent radiation linked to early microbunching, with implications for the laser heater configuration.

JACOW
Openalex Percentile: Top 73%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.