Bunch duration measurements in the APS-U booster

We present the results of time-based, bunch length measurements in the Advanced Photon Source Upgrade booster synchrotron using the bunch duration monitor (BDM) optical diagnostic. The BDM diagnostic is based on the detection of visible-wavelength synchrotron radiation. The detector is a metal-semiconductor-metal device followed by 42 dB of wide-band amplifier gain. Bunch duration is determined by de-convolving the raw output signal with the circuit’s impulse response function. The BDM allows measurement of bunch duration over virtually the entire booster ramp. De-focusing in the optical path was necessary to overcome thermal steering from the in-tunnel mirror. Also, the effects of detector saturation must be considered to ensure a linear response. Presently, the booster increases bunch energy from 425 MeV to 6 GeV. Booster charge varies from 5 nC to 13 nC depending on storage ring operating modes. BDM data reveal that the bunch undergoes large longitudinal oscillations shortly after injection into the booster. The longitudinal oscillations are compared with elegant simulations. These oscillations are a source of injection loss especially at higher charge.

Authors

Publication Details

Journal
JACOW
Published
2026-01-29
DOI
https://doi.org/10.18429/jacow-napac2025-mop019
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bunch duration measurements in the APS-U booster

Osama Mohsen, Joseph Calvey, Jeffrey Dooling
JACOW
Particle Accelerators and Free-Electron Lasers
article

Bunch duration measurements in the APS-U booster

Osama Mohsen, Joseph Calvey, Jeffrey Dooling
article en

Abstract

We present the results of time-based, bunch length measurements in the Advanced Photon Source Upgrade booster synchrotron using the bunch duration monitor (BDM) optical diagnostic. The BDM diagnostic is based on the detection of visible-wavelength synchrotron radiation. The detector is a metal-semiconductor-metal device followed by 42 dB of wide-band amplifier gain. Bunch duration is determined by de-convolving the raw output signal with the circuit’s impulse response function. The BDM allows measurement of bunch duration over virtually the entire booster ramp. De-focusing in the optical path was necessary to overcome thermal steering from the in-tunnel mirror. Also, the effects of detector saturation must be considered to ensure a linear response. Presently, the booster increases bunch energy from 425 MeV to 6 GeV. Booster charge varies from 5 nC to 13 nC depending on storage ring operating modes. BDM data reveal that the bunch undergoes large longitudinal oscillations shortly after injection into the booster. The longitudinal oscillations are compared with elegant simulations. These oscillations are a source of injection loss especially at higher charge.

JACOW
Affordable and clean energy
Openalex Percentile: Top 73%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.