The role of lidocaine spray in reducing pain during intrauterine device insertion

The research examined whether lidocaine spray application to the cervix would decrease the pain experienced during procedures. A double-blind randomised controlled trial included 294 women from July 2022 through February 2023. The study participants received either lidocaine spray (n = 147) or placebo (n = 147) through computerized randomization. The visual analogue scale measured patient pain at six distinct points throughout the procedure. The Beck scales evaluated patients’ levels of anxiety and depression. The main outcome variables consisted of pain measurements obtained during hysterometry and device insertion. The sample size was determined based on prior studies to detect a clinically meaningful difference in VAS scores. Trial registration: ClinicalTrials.gov Identifier: NCT07155785, registered on 13 March 2024. The lidocaine spray group reported an average device insertion pain score of 4.18 ± 3.28 while the placebo group reported 4.24 ± 3.51 (p = 0.788). The pain scores during hysterometry did not differ between groups (3.44 ± 2.77 vs. 3.33 ± 2.93; p = 0.718). Both treatment groups reported severe pain to the same extent with approximately 27% of patients. The pain levels of women increased significantly when their anxiety scores were high regardless of the treatment they received (p < 0.05). Minor variations in operator technique and individual psychophysical differences may have contributed to pain perception but were equally distributed between groups. The application of lidocaine spray failed to provide any pain relief during intrauterine device insertion procedures. Anxiety levels directly affected how much pain patients experienced. It was understood that psychological preparation prior to the procedure may be more important than physical interventions.

Authors

Institutions

Publication Details

Journal
BMC Women s Health
Published
2026-01-29
DOI
https://doi.org/10.1186/s12905-026-04296-3
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The role of lidocaine spray in reducing pain during intrauterine device insertion

Abdülkadir Turgut, Ergul DEMIRCIVI, Canan SATIR OZEL, Aysegul Yildirim et al.
BMC Women s Health
Reproductive Health and Contraception
article

The role of lidocaine spray in reducing pain during intrauterine device insertion

Abdülkadir Turgut, Ergul DEMIRCIVI, Canan SATIR OZEL, Aysegul Yildirim, Serpil Sari
article en

Abstract

The research examined whether lidocaine spray application to the cervix would decrease the pain experienced during procedures. A double-blind randomised controlled trial included 294 women from July 2022 through February 2023. The study participants received either lidocaine spray (n = 147) or placebo (n = 147) through computerized randomization. The visual analogue scale measured patient pain at six distinct points throughout the procedure. The Beck scales evaluated patients’ levels of anxiety and depression. The main outcome variables consisted of pain measurements obtained during hysterometry and device insertion. The sample size was determined based on prior studies to detect a clinically meaningful difference in VAS scores. Trial registration: ClinicalTrials.gov Identifier: NCT07155785, registered on 13 March 2024. The lidocaine spray group reported an average device insertion pain score of 4.18 ± 3.28 while the placebo group reported 4.24 ± 3.51 (p = 0.788). The pain scores during hysterometry did not differ between groups (3.44 ± 2.77 vs. 3.33 ± 2.93; p = 0.718). Both treatment groups reported severe pain to the same extent with approximately 27% of patients. The pain levels of women increased significantly when their anxiety scores were high regardless of the treatment they received (p < 0.05). Minor variations in operator technique and individual psychophysical differences may have contributed to pain perception but were equally distributed between groups. The application of lidocaine spray failed to provide any pain relief during intrauterine device insertion procedures. Anxiety levels directly affected how much pain patients experienced. It was understood that psychological preparation prior to the procedure may be more important than physical interventions.

BMC Women s HealthVol. 26(1)
İstanbul Kanuni Sultan Süleyman Eğitim ve Araştırma Hastanesi (TR), Istanbul Medeniyet University (TR), Istanbul University (TR)
Good health and well-being
Openalex Percentile: Top 75%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.