40 Hz steady-state visually evoked potentials recovered during oscillating transcranial electrical stimulation

Background . Combining Transcranial Electrical Stimulation and Visual Stimulation at the gamma frequency of 40 Hz holds scientific and clinical potential, but requires concurrent electrophysiological measurement to quantify neuronal effects. This poses substantial methodological challenges: electrical stimulation artifacts largely overshadow EEG signals; gamma signals’ amplitude is particularly low; and oculo-muscular confounds overlap in frequency. With appropriate artifact removal, we aimed to record 40 Hz Steady-State Visually Evoked Potentials (SSVEPs) with EEG during frequency-matched electrical stimulation and explore possible interactions. Methods . In three experiments (N = 25 healthy volunteers each), we tested if electrical and visual stimulation might interact depending on which brain areas are electrically stimulated or whether the respective frequencies match—and, importantly, how effectively the data processing pipeline can separate artifacts from genuine neuronal activity. Analysing SSVEPs in the time domain, as opposed to the traditional frequency domain, enabled us to mitigate electrical artifacts flexibly through an adaptive template subtraction approach with millisecond precision. It also allowed us to extract SSVEP waveform information, in addition to amplitude. Compared to previous approaches for low frequencies, our algorithm has improved artifact template fitting, a new interpolation feature, and refined segment rejection criteria. Main Results . We successfully recovered 40 Hz SSVEPs during frequency-matched electrical stimulation applied to central and occipital regions. They closely matched baseline SSVEPs without electrical stimulation in waveform shape. A control condition (no visual stimulation, only electrical) produced uncorrelated low-amplitude signals, further demonstrating robust artifact removal. No interactions between electrical and visual stimulation were found. Significance . We demonstrated how 40 Hz SSVEPs can be reliably measured with EEG during frequency-matched electrical brain stimulation, distinguishing neuronal activity from electrical or physiological confounds. This method now enables fundamental and clinical researchers to combine rhythmic sensory and electrical stimulation in the gamma band and concurrently quantify neuronal electrophysiological effects.

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-09-08
DOI
https://doi.org/10.5167/uzh-283912
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

40 Hz steady-state visually evoked potentials recovered during oscillating transcranial electrical stimulation

Universität Zürich, ZORA
Transcranial Magnetic Stimulation Studies
article

40 Hz steady-state visually evoked potentials recovered during oscillating transcranial electrical stimulation

article en

Abstract

Background . Combining Transcranial Electrical Stimulation and Visual Stimulation at the gamma frequency of 40 Hz holds scientific and clinical potential, but requires concurrent electrophysiological measurement to quantify neuronal effects. This poses substantial methodological challenges: electrical stimulation artifacts largely overshadow EEG signals; gamma signals’ amplitude is particularly low; and oculo-muscular confounds overlap in frequency. With appropriate artifact removal, we aimed to record 40 Hz Steady-State Visually Evoked Potentials (SSVEPs) with EEG during frequency-matched electrical stimulation and explore possible interactions. Methods . In three experiments (N = 25 healthy volunteers each), we tested if electrical and visual stimulation might interact depending on which brain areas are electrically stimulated or whether the respective frequencies match—and, importantly, how effectively the data processing pipeline can separate artifacts from genuine neuronal activity. Analysing SSVEPs in the time domain, as opposed to the traditional frequency domain, enabled us to mitigate electrical artifacts flexibly through an adaptive template subtraction approach with millisecond precision. It also allowed us to extract SSVEP waveform information, in addition to amplitude. Compared to previous approaches for low frequencies, our algorithm has improved artifact template fitting, a new interpolation feature, and refined segment rejection criteria. Main Results . We successfully recovered 40 Hz SSVEPs during frequency-matched electrical stimulation applied to central and occipital regions. They closely matched baseline SSVEPs without electrical stimulation in waveform shape. A control condition (no visual stimulation, only electrical) produced uncorrelated low-amplitude signals, further demonstrating robust artifact removal. No interactions between electrical and visual stimulation were found. Significance . We demonstrated how 40 Hz SSVEPs can be reliably measured with EEG during frequency-matched electrical brain stimulation, distinguishing neuronal activity from electrical or physiological confounds. This method now enables fundamental and clinical researchers to combine rhythmic sensory and electrical stimulation in the gamma band and concurrently quantify neuronal electrophysiological effects.

Universität Zürich, ZORA
Openalex Percentile: Top 34%
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.