Design and Experimental Validation of a 12 GHz High-Gain 4 × 4 Patch Antenna Array for S21 Phase-Based Vital Signs Monitoring

Non-contact monitoring of human vital signs using microwave radar has attracted increasing attention due to its capability to operate unobtrusively and through clothing or light obstacles. In vector network analyzer (VNA)-based radar systems, vital signs can be extracted from phase variations in the forward transmission coefficient S21, whose sensitivity strongly depends on the electromagnetic performance of the antenna system. This work presents the design, optimization, fabrication, and experimental validation of a high-gain 12 GHz 4 × 4 microstrip patch antenna array specifically developed for phase-based vital signs monitoring. The antenna array was progressively optimized through coaxial feeding, slot-based impedance control, stepped transmission line matching, and mitered bends, achieving a simulated gain of 17.8 dBi, a measured gain of 17.06 dBi, a reflection coefficient of -26 dB at 12 GHz, and a total efficiency close to 74%. The antenna performance was experimentally validated in an anechoic chamber and subsequently integrated into a continuous-wave VNA-based radar system. Comparative measurements were conducted against a commercial biconical antenna, a single patch radiator, and an MIMO antenna under identical conditions. Results demonstrate that while respiration can be detected with moderate-gain antennas, reliable heartbeat detection requires high-gain, narrow-beam antennas to enhance phase sensitivity and suppress environmental clutter. The proposed array significantly improves pulse detectability in the (1-1.5) Hz band without relying on advanced signal processing. These findings highlight the critical role of antenna design in S21-based biomedical radar systems and provide practical design guidelines for high-sensitivity non-contact vital signs monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-29
DOI
https://doi.org/10.3390/s26030887
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Experimental Validation of a 12 GHz High-Gain 4 × 4 Patch Antenna Array for S21 Phase-Based Vital Signs Monitoring

David Vătămanu, Ladislau Matekovits, Simona Miclăuş
Sensors
Non-Invasive Vital Sign Monitoring
article

Design and Experimental Validation of a 12 GHz High-Gain 4 × 4 Patch Antenna Array for S21 Phase-Based Vital Signs Monitoring

David Vătămanu, Ladislau Matekovits, Simona Miclăuş
article en

Abstract

Non-contact monitoring of human vital signs using microwave radar has attracted increasing attention due to its capability to operate unobtrusively and through clothing or light obstacles. In vector network analyzer (VNA)-based radar systems, vital signs can be extracted from phase variations in the forward transmission coefficient S21, whose sensitivity strongly depends on the electromagnetic performance of the antenna system. This work presents the design, optimization, fabrication, and experimental validation of a high-gain 12 GHz 4 × 4 microstrip patch antenna array specifically developed for phase-based vital signs monitoring. The antenna array was progressively optimized through coaxial feeding, slot-based impedance control, stepped transmission line matching, and mitered bends, achieving a simulated gain of 17.8 dBi, a measured gain of 17.06 dBi, a reflection coefficient of -26 dB at 12 GHz, and a total efficiency close to 74%. The antenna performance was experimentally validated in an anechoic chamber and subsequently integrated into a continuous-wave VNA-based radar system. Comparative measurements were conducted against a commercial biconical antenna, a single patch radiator, and an MIMO antenna under identical conditions. Results demonstrate that while respiration can be detected with moderate-gain antennas, reliable heartbeat detection requires high-gain, narrow-beam antennas to enhance phase sensitivity and suppress environmental clutter. The proposed array significantly improves pulse detectability in the (1-1.5) Hz band without relying on advanced signal processing. These findings highlight the critical role of antenna design in S21-based biomedical radar systems and provide practical design guidelines for high-sensitivity non-contact vital signs monitoring.

SensorsVol. 26(3)
Technical University of Cluj-Napoca (RO), Politecnico di Torino (IT), Polytechnic University of Timişoara (RO), Institute of Electronics, Computer and Telecommunication Engineering (IT), Nicolae Bălcescu Land Forces Academy (RO), National Research Council (IT)
Openalex Percentile: Top 74%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.