Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI

Introduction: Portable, low-field (LF) magnetic resonance imaging (MRI) has the potential to expand access to neuroimaging in environments where conventional MRI is limited. However, diffusion-weighted imaging (DWI) at LF is challenged by a low signal-to-noise ratio and gradient strength, which may limit diagnostic confidence in acute ischemic stroke (AIS) evaluation, particularly for very small strokes. To address this gap, we evaluated a combination of novel LF-MRI hardware and pulse sequences to enhance lesion detection. Methods: Patients with a suspected diagnosis of AIS were prospectively enrolled at three US centers and underwent single-direction DWI and apparent diffusion coefficient (ADC) imaging on a 0.064 T MRI (v1, Hyperfine Inc.). A multi-direction DWI sequence (comprising 3 orthogonal diffusion direcions) was developed for comparison. Additionally, a next-generation 0.064 T scanner with optimized gradient amplifiers, form factor, and cooling system was evaluated (v2, Hyperfine Inc.). Diagnostic accuracy and the lower limit of lesion detection was calculated for both single-direction and multi-direction images compared to ground-truth MRI (1.5-3 T). Results: A total of 95 patients ( n =62 confirmed ischemic stroke; n =33 stroke mimics) were included. On single-direction images, agreement between assessors regarding lesion detection was κ=0.72, and κ=0.84 on multi-direction images. The positive predictive value for differentiating AIS from stroke mimics was 78.2% on single-direction images and 95% for multi-direction trace maps. On single-direction images, a lesion volume cut-point of 0.6 mL yielded a sensitivity of 89% and specificity of 88%. For multi-direction trace maps, the lesion volume cut-point was 0.4 mL, with a corresponding sensitivity of 86% and specificity of 83%. Multi-direction imaging on the next generation v2 hardware improved image uniformity (p<0.05), reduced scan time by approximately 30% (15 vs. 11 min), and enabled the detection of lesions as small as 0.15 mL. Conclusions: Implementation of DWI optimization strategies on LF-MRI improves detection of very small strokes in a clinically feasible time frame. These advancements highlight the potential role of portable LF-MRI as a diagnostic tool for the evaluation of patients with suspected mild stroke or transient ischemic attack, particulalrly in locations that do not otherwise have ready access to MRI.

Authors

Institutions

Publication Details

Journal
Stroke
Published
2026-01-29
DOI
https://doi.org/10.1161/str.57.suppl_1.wp247
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI

Stephen Bacchi, Matthew Rosen, Shahid M. Nimjee, Nándor Pintér et al.
Stroke
Advanced MRI Techniques and Applications
article

Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI

Stephen Bacchi, Matthew Rosen, Shahid M. Nimjee, Nándor Pintér, Ian Johnson, V Lee, Vinay Jaikumar, Kathryn E. Keenan, Gordon Sze, John E. Kirsch, Olivia Nelson, Hailey Brigger, Jennifer D. Guo, KW Muir, Blair A. Parry, Amelia Demopoulos, Joshua Goldstein, Adam de Havenon, Annabel Sorby-Adams, Adnan H. Siddiqui, W. Taylor Kimberly
article en

Abstract

Introduction: Portable, low-field (LF) magnetic resonance imaging (MRI) has the potential to expand access to neuroimaging in environments where conventional MRI is limited. However, diffusion-weighted imaging (DWI) at LF is challenged by a low signal-to-noise ratio and gradient strength, which may limit diagnostic confidence in acute ischemic stroke (AIS) evaluation, particularly for very small strokes. To address this gap, we evaluated a combination of novel LF-MRI hardware and pulse sequences to enhance lesion detection. Methods: Patients with a suspected diagnosis of AIS were prospectively enrolled at three US centers and underwent single-direction DWI and apparent diffusion coefficient (ADC) imaging on a 0.064 T MRI (v1, Hyperfine Inc.). A multi-direction DWI sequence (comprising 3 orthogonal diffusion direcions) was developed for comparison. Additionally, a next-generation 0.064 T scanner with optimized gradient amplifiers, form factor, and cooling system was evaluated (v2, Hyperfine Inc.). Diagnostic accuracy and the lower limit of lesion detection was calculated for both single-direction and multi-direction images compared to ground-truth MRI (1.5-3 T). Results: A total of 95 patients ( n =62 confirmed ischemic stroke; n =33 stroke mimics) were included. On single-direction images, agreement between assessors regarding lesion detection was κ=0.72, and κ=0.84 on multi-direction images. The positive predictive value for differentiating AIS from stroke mimics was 78.2% on single-direction images and 95% for multi-direction trace maps. On single-direction images, a lesion volume cut-point of 0.6 mL yielded a sensitivity of 89% and specificity of 88%. For multi-direction trace maps, the lesion volume cut-point was 0.4 mL, with a corresponding sensitivity of 86% and specificity of 83%. Multi-direction imaging on the next generation v2 hardware improved image uniformity (p<0.05), reduced scan time by approximately 30% (15 vs. 11 min), and enabled the detection of lesions as small as 0.15 mL. Conclusions: Implementation of DWI optimization strategies on LF-MRI improves detection of very small strokes in a clinically feasible time frame. These advancements highlight the potential role of portable LF-MRI as a diagnostic tool for the evaluation of patients with suspected mild stroke or transient ischemic attack, particulalrly in locations that do not otherwise have ready access to MRI.

StrokeVol. 57(Suppl_1)
National Institute of Standards and Technology (US), Harvard University (US), Yale University (US), Massachusetts General Hospital (US), The Ohio State University (US), University at Buffalo, State University of New York (US), University of Glasgow (GB)
Openalex Percentile: Top 75%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.