Detailed Comparison of Westergren ESR and Automated 18°C ESR Using the YHLO VISION ESR Analyzer: A Comprehensive Assessment in an Indian Cohort

Background Erythrocyte sedimentation rate (ESR) is a widely used, simple, and cost-effective test for diagnosing and monitoring conditions. Although the Westergren method is the gold standard, it has limitations like long processing times, infection risks, and a requirement for citrated blood samples. Automated ESR methods have been developed to overcome these issues. Materials and methods Blood samples were obtained from 4,000 patients who visited the central laboratory for ESR testing after providing informed consent. Each sample was first tested for ESR using the YHLO VISION ESR V4.0 Analyzer (Shenzhen YHLO Biotech Co., Ltd., Shenzhen, China) and subsequently analyzed with the manual Westergren method. The analysis included calculations of mean and standard deviation, Bland-Altman agreement assessment, linear regression, and Mann-Whitney U tests to evaluate the relationship between the two methods. Result Using data from 4,000 patient specimens, results demonstrated good agreement between methods with 94.65% of measurements within acceptable limits, a strong positive linear correlation (r = 0.9809, R² = 0.9621), and a systematic bias of 4.95 mm/h. Both methods effectively distinguished between patients with and without clinical evidence of elevated ESR (p < 0.001). Conclusions The 18°C measurement method provides a viable alternative with high clinical reliability and potential for cost-effectiveness.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-01-29
DOI
https://doi.org/10.7759/cureus.102548
Primary Topic
Blood properties and coagulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detailed Comparison of Westergren ESR and Automated 18°C ESR Using the YHLO VISION ESR Analyzer: A Comprehensive Assessment in an Indian Cohort

Kartavya Kumar Verma, Girish Singh Kshatriya, Himanshu Upadhyay
Cureus
Blood properties and coagulation
article

Detailed Comparison of Westergren ESR and Automated 18°C ESR Using the YHLO VISION ESR Analyzer: A Comprehensive Assessment in an Indian Cohort

Kartavya Kumar Verma, Girish Singh Kshatriya, Himanshu Upadhyay
article en

Abstract

Background Erythrocyte sedimentation rate (ESR) is a widely used, simple, and cost-effective test for diagnosing and monitoring conditions. Although the Westergren method is the gold standard, it has limitations like long processing times, infection risks, and a requirement for citrated blood samples. Automated ESR methods have been developed to overcome these issues. Materials and methods Blood samples were obtained from 4,000 patients who visited the central laboratory for ESR testing after providing informed consent. Each sample was first tested for ESR using the YHLO VISION ESR V4.0 Analyzer (Shenzhen YHLO Biotech Co., Ltd., Shenzhen, China) and subsequently analyzed with the manual Westergren method. The analysis included calculations of mean and standard deviation, Bland-Altman agreement assessment, linear regression, and Mann-Whitney U tests to evaluate the relationship between the two methods. Result Using data from 4,000 patient specimens, results demonstrated good agreement between methods with 94.65% of measurements within acceptable limits, a strong positive linear correlation (r = 0.9809, R² = 0.9621), and a systematic bias of 4.95 mm/h. Both methods effectively distinguished between patients with and without clinical evidence of elevated ESR (p < 0.001). Conclusions The 18°C measurement method provides a viable alternative with high clinical reliability and potential for cost-effectiveness.

CureusVol. 18(1)
All India Institute of Medical Sciences Raipur (IN), Pandit Ravishankar Shukla University (IN), HLL Lifecare (India) (IN), Government Medical College (IN)
Openalex Percentile: Top 75%
Blood properties and coagulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies