Determination of Gentamicin: Development and Validation of a Sensitive UPLC-MS/MS Assay According to the European Medicines Agency Guideline

<b>Background/Objectives</b>: Gentamicin (GEN) is an aminoglycoside antibiotic used in veterinary medicine to treat infections caused mainly by Gram-negative bacteria. GEN is a mixture of pharmacologically active components, known as isoforms. The objective was to develop and validate a sensitive, accurate, and precise Ultra-Performance Liquid Chromatography with triple quadrupole mass detector (UPLC-MS/MS) method to quantify the different GEN isoforms in pig plasma and feces using streptomycin as an internal standard. <b>Methods</b>: Solid-phase extraction (SPE) was carried out. A high-strength silica (50 × 2.1 mm, 1.8 µm) column was used for chromatographic separation and a mobile phase of 0.26% HFBA in water (A) and acetonitrile (B) was delivered in a gradient with a flow rate of 0.5 mL/min. The column temperature was 40 °C and the sample injection volume was 30 µL. <b>Results</b>: The method showed good selectivity and specificity, with no interfering peaks. Calibration curves were linear in the range from 0.05 to 0.3 µg/mL for all isoforms in both matrices. Within- and between-run precision and accuracy were satisfactory for the lower limit of quantification (LLOQ), with coefficients of variation (CV) ≤ 13.4% and deviations ≤ 116.5% in plasma and CV ≤ 12.3% with deviations ≤ 101.7% in feces. No carry-over was observed, and analyte stability was confirmed under different storage conditions. <b>Conclusions</b>: The method development fulfilled all validation criteria established by the European Medicine Agency Guideline (EMA/CHMP/ICH/172948/2019). Moreover, the applicability of the method in clinical practice was demonstrated by the quantification of GEN in plasma and feces samples from pigs.

Authors

Institutions

Publication Details

Journal
Antibiotics
Published
2026-01-28
DOI
https://doi.org/10.3390/antibiotics15020130
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Gentamicin: Development and Validation of a Sensitive UPLC-MS/MS Assay According to the European Medicines Agency Guideline

C. López, Nélida Lemus Fernández, Ana Sahagun, Beatriz Romero et al.
Antibiotics
Antibiotics Pharmacokinetics and Efficacy
article

Determination of Gentamicin: Development and Validation of a Sensitive UPLC-MS/MS Assay According to the European Medicines Agency Guideline

C. López, Nélida Lemus Fernández, Ana Sahagun, Beatriz Romero, Raul De la Puente, Eslí Vázquez, M. Jose Diez, Raquel Diez
article en

Abstract

<b>Background/Objectives</b>: Gentamicin (GEN) is an aminoglycoside antibiotic used in veterinary medicine to treat infections caused mainly by Gram-negative bacteria. GEN is a mixture of pharmacologically active components, known as isoforms. The objective was to develop and validate a sensitive, accurate, and precise Ultra-Performance Liquid Chromatography with triple quadrupole mass detector (UPLC-MS/MS) method to quantify the different GEN isoforms in pig plasma and feces using streptomycin as an internal standard. <b>Methods</b>: Solid-phase extraction (SPE) was carried out. A high-strength silica (50 × 2.1 mm, 1.8 µm) column was used for chromatographic separation and a mobile phase of 0.26% HFBA in water (A) and acetonitrile (B) was delivered in a gradient with a flow rate of 0.5 mL/min. The column temperature was 40 °C and the sample injection volume was 30 µL. <b>Results</b>: The method showed good selectivity and specificity, with no interfering peaks. Calibration curves were linear in the range from 0.05 to 0.3 µg/mL for all isoforms in both matrices. Within- and between-run precision and accuracy were satisfactory for the lower limit of quantification (LLOQ), with coefficients of variation (CV) ≤ 13.4% and deviations ≤ 116.5% in plasma and CV ≤ 12.3% with deviations ≤ 101.7% in feces. No carry-over was observed, and analyte stability was confirmed under different storage conditions. <b>Conclusions</b>: The method development fulfilled all validation criteria established by the European Medicine Agency Guideline (EMA/CHMP/ICH/172948/2019). Moreover, the applicability of the method in clinical practice was demonstrated by the quantification of GEN in plasma and feces samples from pigs.

AntibioticsVol. 15(2)
Universidad de León (ES)
Openalex Percentile: Top 73%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Gentamicin: Development and Validation of a Sensitive UPLC-MS/MS Assay According to the European Medicines Agency Guideline — C. López, Nélida Lemus Fernández, et al. · Antibiotics (2026) | TGRS Research Map | TGRS